Brother International HL-2600CN Service Manual - Page 224
Interlock Switch Front for Front Cover 2, Disconnect the connector.
View all Brother International HL-2600CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 224 highlights
4.1.7 Interlock Switch (Front) (for Front Cover 2) 1) Remove the set screw (1 pc.) to remove the SW ASSY from the printer. 2) Disconnect the connector. SW ASSY Fig.7-17 3) Release the two hooks and remove the interlock switch from the SW base F. Hook SW base F Interlock switch Fig.7-18 CAUTION Since the interlock switch is an important safety item, after installation confirm that the switch operates correctly. VII-13
VII-13
4.1.7
Interlock Switch (Front) (for Front Cover 2)
1) Remove the set screw (1 pc.) to remove the SW ASSY from the printer.
2) Disconnect the connector.
Fig.7-17
3) Release the two hooks and remove the interlock switch from the SW base F.
Fig.7-18
CAUTION
±
Since the interlock switch is an important safety item, after installation confirm that the
switch operates correctly.
SW ASSY
Interlock switch
Hook
SW base F