Sequence of Disassembling 1) After turning off the remote switch and power supply, unplug the power code from the power outlet. 2) Open the paper exit unit cover 2. 3) Slacken the two securing screws securing the fusing unit. 4) Holding the handles at both ends of the fusing unit and remove the fusing unit from the printer. 5) Remove the oil bottle and the fuser cleaner. Screw Fig.6-19 VI-24
![](/manual_guide/products/brother-international-hl2600cn-service-manual-a175c80/195.png)
VI-24
<Work Procedure>
Sequence of Disassembling
1)
After turning off the remote switch and power supply, unplug the power code
from the power outlet.
2)
Open the paper exit unit cover 2.
3)
Slacken the two securing screws securing the fusing unit.
4)
Holding the handles at both ends of the fusing unit and remove the fusing unit
from the printer.
5)
Remove the oil bottle and the fuser cleaner.
Fig.6-19
Screw