Brother International HL-2600CN Service Manual - Page 169
Initial Setting of Engine NVRAM, <Purpose>, <Procedures of Setting>
![]() |
View all Brother International HL-2600CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
3.4.5 Initial Setting of Engine NVRAM Implement the initial setting at the replacement of MCTL PWB 2 after clearing the contents of NVRAM. The number of images for each color will be reset when changing the MCTL PWB 2 or executing NVRAM INITIAL. 1) Before replacing the MCTL PWB 2, confirm the contents of the NVRAM for the following items. "Factory Mode" Code 43 43 44 45 45 45 45 45 47 48 Subject MARGIN ADJUST MARGIN ADJUST LIFE PERIOD SET LP TUNE UP THV TUNE UP DBV TUNE UP CBV TUNE UP FBV TUNE UP TOTAL PAGE SET EACH IMAGE SET Confirmation Value Top Margin Set Value (Default in ordinary case) Left Margin Set Value(Default in ordinary case) Life Period Set Value(Default in ordinary case) Adjustment Value ("0" in ordinary case) Adjustment Value ("0" in ordinary case) Adjustment Value ("0" in ordinary case) Adjustment Value ("0" in ordinary case) Adjustment Value ("0" in ordinary case) Total Print Count Image Count of 4 Colors 2) Execute 46 NVRAM INITIAL in the Factory Mode. 3) After implementing the NVRAM INITIAL, input the values obtained in procedure 1) into the NVRAM to complete the settings. V-44
![](/manual_guide/products/brother-international-hl2600cn-service-manual-a175c80/169.png)