Dell PowerEdge C6220 II Hardware Owners Manual - Page 299
Getting Help
View all Dell PowerEdge C6220 II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 299 highlights
8 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. 9 Enter the System Setup program and check the system memory settings. See "Main Screen" on page 73. If the problem is not resolved, proceed with the next step. 10 Turn off the system and attached peripherals, and disconnect the system from the power source. 11 Remove the system-board assembly. See "Removing a System-Board Assembly" on page 149. 12 If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module. 13 To troubleshoot an unspecified faulty memory module, replace the memory module in the first memory module socket with a module of the same type and capacity. See "Installing the Memory Modules" on page 218. 14 Install the system-board assembly. See "Removing a System-Board Assembly" on page 149. 15 Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. 16 As the system boots, observe any error message that appears and the diagnostic indicators on the front of the system. 17 If the memory problem is still indicated, repeat step 10 through step 16 for each memory module installed. If the problem persists after all memory modules have been checked, see "Getting Help" on page 323. Troubleshooting Your System | 299