Dell PowerEdge M710 Fabric OS Command Reference Manual Supporting Fabric - Page 108
To display bottleneck configuration details for the switch
View all Dell PowerEdge M710 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
2 bottleneckMon To display the bottleneck statistic for every port in the switch including the union of all individual port statistics: switch:admin> bottleneckmon --show -interval 5 -span 30 * Wed Jan 13 18:54:35 UTC 2010 From To 0 1 2 3 4 5 Jan 13 18:54:05 Jan 13 18:54:10 20.00 20.00 0.00 80.00 20.00 100.00 From To 5 6 7 8 UNION Jan 13 18:54:05 Jan 13 18:54:10 40.00 0.00 0.00 20.00 100.00 From To 0 1 2 3 4 5 Jan 13 18:54:10 Jan 13 18:54:15 0.00 0.00 20.00 40.00 20.00 0.00 From To 5 6 7 8 UNION Jan 13 18:54:10 Jul 13 18:54:15 0.00 20.00 0.00 0.00 40.00 To display only the union statistic for the switch: switch:admin> bottleneckmon --show -interval 5 -span 30 Wed Jan 13 18:54:35 UTC 2010 Percentage of From To affected secs Jan 13 18:54:05 Jan 13 18:54:10 80.00 Jan 13 18:54:10 Jan 13 18:54:15 20.00 Jan 13 18:54:15 Jan 13 18:54:20 80.00 Jan 13 18:54:20 Jan 13 18:54:25 0.00 Jan 13 18:54:25 Jan 13 18:54:30 0.00 Jan 13 18:54:30 Jan 13 18:54:35 40.00 To display bottleneck configuration details for the switch: switch:admin> bottleneckmon --status Bottleneck detection - Enabled Switch-wide alerting parameters: Alerts - Yes Congestion threshold for alert - 0.800 Latency threshold for alert - 0.100 Averaging time for alert - 300 seconds Quiet time for alert - 300 seconds Per-port overrides for alert parameters: Slot Port Alerts? LatencyThresh CongestionThresh Time(s) QTime(s) 0 1 Y 0.990 0.900 3000 600 0 2 Y 0.990 0.900 4000 600 76 Fabric OS Command Reference 53-1001764-02