Dell PowerEdge M710 Fabric OS Command Reference Manual Supporting Fabric - Page 968
The ge0 port is a copper port default. The ge1 has an SFP installed copper or optical
View all Dell PowerEdge M710 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 968 highlights
2 switchShow To display blade information and port names: switch:admin> switchshow -slot 5 -portname FC Router: OFF Allow XISL Use: OFF LS Attributes:[FID: 128, Base Switch: No, Default Switch: Yes, Address Mode 0] Slot Blade Type ID Status 5 COREBLADE 52 ENABLED Index Slot Port Name 384 5 0 MyName_portname0 385 5 1 ------ 386 5 2 ------ To display the domain ID offset on a switch in interop mode 2: switch:admin> switchshow switchName: WT_Pulsar_77 switchType: 32.0 switchState: Online switchMode: McDATA Fabric switchRole: Principal DomainIDOffset: 0x20 switchDomain: 2 switchId: fffc25 switchWwn: 10:00:00:05:1e:35:71:8b zoning: OFF switchBeacon: OFF FC Router: OFF FC Router BB Fabric ID: 1 [output truncated] To display media type information (relevant output excerpts only): • The following example shows switchshow output for the ge0 and ge1 ports on a Brocade 7800. The ge0 port is a copper port (default). The ge1 has an SFP installed (copper or optical): [...] ge0 cu ge1 id ge2 -ge3 -ge4 id ge5 -[...] 1G No_Sync FCIP Copper 1G No_Light FCIP 1G No_Module FCIP 1G No_Module FCIP 1G Online FCIP 1G No_Module FCIP • This example shows switchshow output for a Brocade 5100. Port 31 has an SFP installed. Nothing is installed on Port 30. [...] 31 31 421f00 id 32 32 422000 -[...] N4 In_Sync FC Disabled N8 No_Module FC Disabled 936 Fabric OS Command Reference 53-1001764-02