Dell PowerEdge T310 Hardware Owner's Manual - Page 105
Removing a Non-Redundant Power Supply, hard drives and optical drive.
View all Dell PowerEdge T310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
Removing a Non-Redundant Power Supply 1 Turn off the system and all attached peripherals. 2 Disconnect the power cable from the power supply. 3 Open the system. See "Opening the System" on page 85. 4 Disconnect all cables from the power supply to the system board, hard drives and optical drive. 5 Loosen the three screws securing the power supply to the chassis and lift the power supply to remove it from the chassis. See Figure 3-15. Figure 3-15. Removing and Replacing a Non-Redundant Power Supply 1 2 1 non-redundant power supply 2 screws (3) Installing System Components 105
Installing System Components
105
Removing a Non-Redundant Power Supply
1
Turn off the system and all attached peripherals.
2
Disconnect the power cable from the power supply.
3
Open the system. See "Opening the System" on page 85.
4
Disconnect all cables from the power supply to the system board,
hard drives and optical drive.
5
Loosen the three screws securing the power supply to the chassis and
lift the power supply to remove it from the chassis. See Figure 3-15.
Figure 3-15.
Removing and Replacing a Non-Redundant Power Supply
1
non-redundant power supply
2
screws (3)
2
1