Dell PowerEdge T310 Hardware Owner's Manual - Page 33
E171F PCIe fatal, E1715 Fatal I/O - clear sel
View all Dell PowerEdge T310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Table 1-2. LCD Status Messages (continued) Code Text Causes Corrective Actions E1715 Fatal I/O The system BIOS has Error. Review determined there & clear SEL. has been a fatal error in the system. Check the SEL for more information, and then clear the SEL. Remove AC power to the system for 10 seconds, and restart the system. If the problem persists, see "Getting Help" on page 177. E1716 Chipset IERR Bus ## Dev ## Function ##. Review & clear SEL. The system BIOS has reported a chipset internal error that resides in bus ##, device ##, function ##. Check the SEL for more information, and then clear the SEL. Remove AC power to the system for 10 seconds, and restart the system. If the problem persists, see "Getting Help" on page 177. E1717 CPU # The system BIOS has internal determined that the error. Review processor has had an & clear SEL. internal error. Check the SEL for more information, and then clear the SEL. Remove AC power to the system for 10 seconds, and restart the system. If the problem persists, see "Getting Help" on page 177. E171F PCIe fatal error on Bus ## Device ## Function ## The system BIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##. Remove and reseat the PCIe expansion cards. If the problem persists, see "Troubleshooting Expansion Cards" on page 162. About Your System 33