Table 1-3. System Messages (continued) Message Causes Sector not found Faulty hard drive, USB Seek error device, or USB medium. Seek operation failed Shutdown failure General system error. The amount of system memory has changed Memory has been added or removed or a memory module may be faulty. Corrective Actions Replace the USB medium or device. Ensure that the USB or SAS backplane cables are properly connected. See "Troubleshooting a USB Device" on page 148 or "Troubleshooting a Hard Drive" on page 160 for the appropriate drive(s) installed in your system. See "Getting Help" on page 177. If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module. See "Troubleshooting System Memory" on page 155. 48 About Your System