Dell PowerEdge T310 Hardware Owner's Manual - Page 38
E2111 SBE log, I1912 SEL full. - chassis
View all Dell PowerEdge T310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Table 1-2. LCD Status Messages (continued) Code Text Causes Corrective Actions E2111 SBE log disabled on DIMM ##. Reseat DIMM. The system BIOS has Remove AC power to the disabled memory single-bit system for 10 seconds and error (SBE) logging and restart the system. will not log any more SBEs If the problem persists, until the system is see "Troubleshooting rebooted. "##" represents System Memory" on the memory module page 155. implicated by the BIOS. E2113 Mem mirror OFF on DIMM ## & ##. Power cycle AC. The system BIOS has Remove AC power to the disabled memory mirroring system for 10 seconds and because it has determined restart the system. one half of the mirror has had too many errors. "## & ##" represents the memory module pair implicated by the BIOS. If the problem persists, see "Troubleshooting System Memory" on page 155. I1910 Intrusion System cover has been detected. removed. Check chassis cover. Information only. I1911 LCD Log Full. Check SEL to review all Errors. LCD overflow message. A maximum of ten error messages can be displayed sequentially on the LCD. The eleventh message instructs the user to check the SEL for details on the events. Check the SEL for details on the events. Remove AC power to the system for 10 seconds or clear the SEL. I1912 SEL full. Review & clear log. The SEL is full of events and is unable to log any more. Check the SEL for more information and then clear the SEL. 38 About Your System