Dell PowerEdge T310 Hardware Owner's Manual - Page 30
E161C Power Supply - power supply failure
View all Dell PowerEdge T310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Table 1-2. LCD Status Messages (continued) Code Text Causes Corrective Actions E1422 CPU # machine The system BIOS has check error. reported a machine Power cycle check error. AC. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 177. E1610 Power Supply # (### W) missing. Check power supply. Specified power supply was removed or is missing from the system. See "Troubleshooting Power Supplies" on page 153. E1614 Power Supply Specified power supply has See "Troubleshooting # (### W) failed. Power Supplies" on error. Check page 153. power supply. E1618 Predictive failure on Power Supply # (### W). Check PSU. A power supply fan failure, See "Troubleshooting an over-temperature Power Supplies" on condition, or power supply page 153. communication error has caused the predictive warning of an impending power supply failure. E161C Power Supply # (### W) lost AC power. Check PSU cables. Specified power supply is Check the AC power attached to the system, but source for the specified it has lost its AC input. power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 153. E1620 Power Supply # (### W) AC power error. Check PSU cables. Specified power supply's AC input is outside of the allowable range. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supplies" on page 153. 30 About Your System