Dell PowerEdge T310 Hardware Owner's Manual - Page 40
Table 1-3., System Messages, Message, Causes, Corrective Actions - memory upgrade
View all Dell PowerEdge T310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Table 1-3. System Messages Message Causes Corrective Actions Alert! iDRAC6 not responding. Rebooting. The iDRAC6 is not responding to BIOS communication either because it is not functioning properly or has not completed initialization. The system will reboot. Wait for the system to reboot. Alert! iDRAC6 not responding. Power required may exceed PSU wattage. Alert! Continuing system boot accepts the risk that system may power down without warning. The iDRAC6 is hung. The iDRAC6 was remotely reset while system was booting After AC recovery, the iDRAC6 takes longer than normal to boot. Remove AC power to the system for 10 seconds and restart the system. Alert! Power required exceeds PSU wattage. Check PSU and system configuration. Alert! Continuing system boot accepts the risk that system may power down without warning. The system configuration of processor, memory modules, and expansion cards may not be supported by the power supplies. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. See "Chassis Intrusion Switch" on page 134. Alert! System fatal error during previous boot. An error caused the system to reboot. Check other system messages for additional information for possible causes. 40 About Your System