HP A7533A HP StorageWorks Fabric OS 6.1.1 administrator guide (5697-0235, Dece - Page 264
iSCSI Virtual Target Configuration
![]() |
UPC - 829160830858
View all HP A7533A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 264 highlights
4. (Optional) Issue the portCfg command to define static routes to reach the destination IP through a preferred gateway: switch:admin> portcfg iproute 3/ge0 create 0.0.0.0 0.0.0.0 30.0.0.1 1 Operation Succeeded The gateway must be on the same subnet as the GbE port. You can specify a maximum of 32 routes per GbE port. 5. (Optional) Verify the route as follows: switch:admin> portshow iproute 3/ge0 Slot: 3 Port: ge0 IP AddressMaskGatewayMetricFlags 0.0.0.0 0.0.0.0 30.0.0.1 1 30.0.0.0 255.255.0.0 30.0.127.30 0 Interface 6. Issue the portCmd --ping command to verify the network connection: switch:admin> portcmd --ping 3/ge0 -s 30.0.127.30 -d 30.0.0.1 Pinging 30.0.0.1 from ip interface 30.0.127.30 on 3/ge0 with 64 bytes of data Reply from 30.0.0.1: bytes=64 rtt=0ms ttl=255 Reply from 30.0.0.1: bytes=64 rtt=0ms ttl=255 Reply from 30.0.0.1: bytes=64 rtt=0ms ttl=255 Reply from 30.0.0.1: bytes=64 rtt=0ms ttl=255 Ping Statistics for 30.0.0.1: Packets: Sent = 4, Received = 4, Loss = 0 ( 0 percent loss) Min RTT = 0ms, Max RTT = 0ms Average = 0ms 7. (Optional) Issue the portCfg arp command to configure additional ARP entries: switch:admin> portcfg arp 3/ge0 add 30.0.30.11 00:0F:1F:69:99:88 Operation Succeeded 8. (Optional) Verify the entry by issuing the portShow command. switch:admin> portshow arp 3/ge0 Slot: 3 Port: ge0 IP AddressMac AddressFlags 30.0.30.214 00:c0:dd:07:81:13 Resolved 30.0.0.1 00:11:93:58:fd:7f Resolved 30.0.30.11 00:0f:1f:69:99:88 Permanent Resolved iSCSI Virtual Target Configuration Configuring an iSCSI environment involves creating iSCSI virtual targets (VTs), discovery domains (DDs), discovery domain sets (DDSets), and defining iSCSI VT-iSCSI initiator authentication. NOTE: You can also configure iSCSI virtual targets through the Web Tools Graphical User Interface as an alternative to the command line interface. See the Web Tools Administrator's Guide for descriptions of GUI-based configuration procedures. Create iSCSI VTs using the LUN values of FC targets. The FC target must be accessible from the iSCSI gateway. iSCSI VTs can be automatically generated or manually created. After mapping iSCSI targets do not move the targets out of Administrative Domain 0 (AD0), unless you then explicitly add them back to AD0. 264 iSCSI Gateway services
![](/manual_guide/products/hewlettpackard-ae370a-hp-storageworks-fabric-os-611-administrator-guide-56970235-2009-a28315e/264.png)