HP Dx5150 HP Business Desktop dx5150 Series Service Reference Guide, 1st Editi - Page 61

Removal and Replacement Procedures, Microtower MT Chassis

Page 61 highlights

6 Removal and Replacement Procedures- Microtower (MT) Chassis Adherence to the procedures and precautions described in this chapter is essential for proper service. After completing all necessary removal and replacement procedures, run the Diagnostics utility to verify that all components operate properly. ✎ Not all features listed in this guide are available on all computers. 6.1 Preparation for Disassembly See Chapter 5, "Identifying the Chassis, Routine Care, and Disassembly Preparation," for initial procedures. 1. Remove/disengage any security devices that prohibit opening the computer (Section 6.2.1, "Installing a Cable Lock," and Section 6.2.2, "Installing a Padlock"). 2. Close any open software applications. 3. Exit the operating system. 4. Remove any diskette, compact disc, or MultiBay device from the computer. 5. Turn off the computer and any peripheral devices that are connected to it. Ä CAUTION: Turn off the computer before disconnecting any cables. Ä CAUTION: Regardless of the power-on state, voltage is always present on the system board as long as the system is plugged into an active AC outlet. In some systems, the cooling fan is on even when the computer is in the "Standby" or "Suspend" mode. Always disconnect the power cord before servicing a unit. 6. Disconnect the power cord from the electrical outlet and then from the computer. 7. Disconnect all peripheral device cables from the computer. ✎ During disassembly, label each cable as you remove it, noting its position and routing. Keep all screws with the units removed. Ä CAUTION: The screws used in the computer are of different thread sizes and lengths; using the wrong screw in an application may damage the unit. Service Reference Guide, dx5150 361685-001 6-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182

Service Reference Guide, dx5150
361685-001
6–1
6
Removal and Replacement Procedures—
Microtower (MT) Chassis
Adherence to the procedures and precautions described in this chapter is essential for proper
service. After completing all necessary removal and replacement procedures, run the Diagnostics
utility to verify that all components operate properly.
Not all features listed in this guide are available on all computers.
6.1 Preparation for Disassembly
See
Chapter 5, “Identifying the Chassis, Routine Care, and Disassembly Preparation,”
for initial
procedures.
1. Remove/disengage any security devices that prohibit opening the computer (
Section 6.2.1,
“Installing a Cable Lock,”
and
Section 6.2.2, “Installing a Padlock”
).
2. Close any open software applications.
3. Exit the operating system.
4. Remove any diskette, compact disc, or MultiBay device from the computer.
5. Turn off the computer and any peripheral devices that are connected to it.
Ä
CAUTION:
Turn off the computer before disconnecting any cables.
Ä
CAUTION:
Regardless of the power-on state, voltage is always present on the system board as long as
the system is plugged into an active AC outlet. In some systems, the cooling fan is on even when the
computer is in the “Standby” or “Suspend” mode. Always disconnect the power cord before servicing a
unit.
6. Disconnect the power cord from the electrical outlet and then from the computer.
7. Disconnect all peripheral device cables from the computer.
During disassembly, label each cable as you remove it, noting its position and routing. Keep all
screws with the units removed.
Ä
CAUTION:
The screws used in the computer are of different thread sizes and lengths; using the wrong
screw in an application may damage the unit.