HP LH4r HP Netserver LH 6000 Installation Guide - Page 167
Power Requirements
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
Appendix A Specifications Weight and Dimensions NOTE A fully loaded HP NetServer can weigh up to 173 lbs. (78.5 kgs). Follow local regulations, and use one person for every 40 pounds of HP NetServer weight when lifting it. HP NetServer LH 6000 Height Width Depth Weight HP NetServer LH 6000r Height Width Depth Weight 494.8 mm (19.5 in) 350.5 mm (13.8 in) 724.2 mm (28.5 in) 72.6 - 78.5 kg (160 - 173 lb.) 354.7 mm (14 in) 482.6 mm (19 in) 749.2 mm (29.5 in) 72.6 - 78.5 kg (160 - 173 lb.) Power Requirements Power Supply Specifications: Three power supplies, plus one for redundancy Power supply type Wide range, PFC Input voltages: Nominal: 100 to 240 VAC, 11.7A/5.6 A at 50/60 Hz Range: 90 to 264 VAC at 47 - 63 Hz Power availability: 780 W continuous Minimum System Requirements Voltage Volt/Amps Amps Watts 100 1177 11.7 1166 120 1153 9.6 1141 200 1120 5.6 1099 230 1117 4.9 1095 159