HP LH4r HP Netserver LH 6000 Installation Guide - Page 86

Testing the Processor, Re-installing the NOS, Removing a Processor Module

Page 86 highlights

Chapter 7 Installing Additional Processors Testing the Processor After you power on the HP NetServer, check boot messages to see whether or not the system detects the additional processor. If boot messages indicate that the additional processor has not been found, check the installation of the processor and the VRM and verify that the speed and cache size are correct. Re-installing the NOS You may have to re-install your Network Operating System in order to use the additional processor. If you have gone from a single-processor to multi-processor configuration, check your NOS documentation or the README First file and Configuration Advisor utilities on the HP NetServer Navigator CD-ROM. This completes the installation of the additional processor. Removing a Processor Module Use the same procedure as above, and simply remove the processor module rather than add it. Be sure to remove the associated VRM and keep it with the processor. CAUTION Replace the removed processor with a terminator/baffle. 78

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186

Chapter
7
Installing Additional Processors
78
Testing the Processor
After you power on the HP NetServer, check boot messages to see whether or not
the system detects the additional processor. If boot messages indicate that the
additional processor has not been found, check the installation of the processor
and the VRM and verify that the speed and cache size are correct.
Re-installing the NOS
You may have to re-install your Network Operating System in order to use the
additional processor. If you have gone from a single-processor to multi-processor
configuration, check your NOS documentation or the README First file and
Configuration Advisor utilities on the
HP NetServer Navigator CD-ROM
.
This completes the installation of the additional processor.
Removing a Processor Module
Use the same procedure as above, and simply remove the processor module rather
than add it. Be sure to remove the associated VRM and keep it with the processor.
CAUTION
Replace the removed processor with a terminator/baffle.