HP Workstation x4000 hp workstation x4000 - Technical Reference manual - Windo - Page 221

Reseat PCI and AGP I/O cards., Reseat the memory expander card.

Page 221 highlights

Troubleshooting Understanding the Diag LEDs Table 11-1 Diag LED Patterns (R = Red, Y = Yellow, G = Green, q = Off) Pattern Description qYRY 12V power circuitry error. qYRG 2.5 V RDRAM power circuitry error. Possible Solutionsa 1. Reseat PCI and AGP I/O cards. 2. Try removing the I/O cards one at a time, restarting the Workstation each time. If it appears the error is being caused by one card, replace the card. 3. Replace the power supply as described in "System Memory" on page 159. 4. Replace the system board as described in "System Board" on page 186. 1. Reseat the memory expander card. 2. If the memory expander card has a separate voltage regulator module, reseat or replace the voltage regulator module. 3. Replace the RIMMs or CRIMMs as described in "System Memory" on page 159. 4. Replace the memory expander card. Chapter 11 221

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238

Troubleshooting
Understanding the Diag LEDs
Chapter 11
221
YRY
12V power circuitry error.
1.
Reseat PCI and AGP I/O cards.
2.
Try removing the I/O cards one at a
time, restarting the Workstation
each time. If it appears the error is
being caused by one card, replace
the card.
3.
Replace the power supply as
described in “System Memory” on
page 159.
4.
Replace the system board as
described in “System Board” on
page 186.
YRG
2.5 V RDRAM power circuitry error.
1.
Reseat the memory expander card.
2.
If the memory expander card has a
separate voltage regulator module,
reseat or replace the voltage
regulator module.
3.
Replace the RIMMs or CRIMMs as
described in “System Memory” on
page 159.
4.
Replace the memory expander
card.
Table 11-1
Diag LED Patterns
(R = Red, Y = Yellow, G = Green,
= Off)
Pattern
Description
Possible Solutions
a