HP Workstation x4000 hp workstation x4000 - Technical Reference manual - Windo - Page 88
Resetting the Power Supply, Power Consumption and Cooling, Power Supply,
![]() |
View all HP Workstation x4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Power Specifications Power Supply Resetting the Power Supply If an overload triggers the power supply's overload protection, all power is immediately cut. To reset the power supply unit: 1. Disconnect the power cord. 2. Determine what caused the overload, and fix the problem. 3. Reconnect the power cord, and reboot the workstation. When you power down the Workstation through the operating system, power consumption falls below the low power consumption (refer to the table on page 88), but doesn't reach zero. This on/off feature extends the power supply's lifetime. Power Consumption and Cooling The power consumption and acoustics listed in the following table are valid for a typical maximum configuration: • two processors • 768 MB memory • two hard disk drives • DVD ROM • 3.5-inch floppy disk drive • graphics card All information in this section is based on primary power consumptions. Input power consumption (approximate values) • Typical operating mode • Standby mode (Windows 2000 only) • Hibernate mode (Windows 2000 only) a. 1 W = 3.4121Btu/h 230V/50Hz and 115V/60Hz 360 W 150 W < 11 W 1228.4 Btu/ha 511.8 Btu/h < 37.33 Btu/h 88 Chapter 6