IBM 86645RY Hardware Maintenance Manual - Page 207

Beep/Symptom, Run Diagnostics

Page 207 highlights

Beep/Symptom 3-1-2 (Interval timer channel 2 failed) 3-1-3 (RAM test failed above address 0FFFFH) 3-1-4 (Time-Of-Day clock failed) 3-2-1 (Serial port failed) 3-2-2 (Parallel port failed) 3-2-3 (Math coprocessor failed) 3-2-4 (Failure comparing CMOS memory size against actual) 3-3-1 (Memory size mismatch occurred) 3-3-2 (Critical SMBUS error occurred) 3-3-3 (No memory in system) Two Short Beeps (Information only, the configuration has changed) Three Short Beeps One Continuous Beep Repeating Short Beeps One Long and One Short Beep FRU/Action 1. System Board 1. DIMM 2. Processor Board 3. System Board 1. Battery 2. System Board 1. System Board 1. System Board 1. Optional Processor (if installed) 2. Processor 3. Processor Board 1. DIMM 2. Battery 1. DIMM 2. Battery 1. Disconnect the server power cord from outlet, wait 30 seconds and retry. 2. Memory DIMMs 3. Processor Board 1. Install or reseat the memory modules 2. DIMMs 3. Processor Board 4. System Board 1. Run Diagnostics 2. Run Configuration/Setup 3. Processor Board 1. DIMM 2. Processor Board 3. System Board 1. Processor 2. Optional Processor (if installed) 3. Processor Board 4. System Board 1. Keyboard 2. System Board 1. Video adapter (if present) 2. System Board 3. Netfinity 5600 - Type 8664 199

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276

Beep/Symptom
FRU/Action
3-1-2
(Interval timer channel 2
failed)
1.
System Board
3-1-3
(RAM test failed above
address 0FFFFH)
1.
DIMM
2.
Processor Board
3.
System Board
3-1-4
(Time-Of-Day clock failed)
1.
Battery
2.
System Board
3-2-1
(Serial port failed)
1.
System Board
3-2-2
(Parallel port failed)
1.
System Board
3-2-3
(Math coprocessor failed)
1.
Optional Processor
(if installed)
2.
Processor
3.
Processor Board
3-2-4
(Failure comparing CMOS
memory size against actual)
1.
DIMM
2.
Battery
3-3-1
(Memory size mismatch
occurred)
1.
DIMM
2.
Battery
3-3-2
(Critical SMBUS error
occurred)
1.
Disconnect the
server power cord
from outlet, wait 30
seconds and retry.
2.
Memory DIMMs
3.
Processor Board
3-3-3
(No memory in system)
1.
Install or reseat the
memory modules
2.
DIMMs
3.
Processor Board
4.
System Board
Two Short Beeps
(Information only, the
configuration has changed)
1.
Run Diagnostics
2.
Run
Configuration/Setup
3.
Processor Board
Three Short Beeps
1.
DIMM
2.
Processor Board
3.
System Board
One Continuous Beep
1.
Processor
2.
Optional Processor
(if installed)
3.
Processor Board
4.
System Board
Repeating Short Beeps
1.
Keyboard
2.
System Board
One Long and One Short
Beep
1.
Video adapter
(if present)
2.
System Board
3.
Netfinity 5600 - Type 8664
199