IBM 86645RY Hardware Maintenance Manual - Page 220
Error Code/Symptom, FRU/Action, Cable, System Board, Fixed Disk Cables, Configuration/Setup
View all IBM 86645RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 220 highlights
Error Code/Symptom 1304 (Cable to Diagnostic LED panel not detected. 1600, 1601 (The system is able to communicate to the Service Processor, but the Service Processor failed to respond at the start of POST.) Do the following before replacing a FRU: 1. Remove the ac power to the system, wait 20 seconds; then, re-connect the ac power. Wait 30 seconds; then, power-on the system. 2. Flash update the Service Processor. 3. Check the SP reset jumper, if fitted. 1762 (Fixed Disk Configuration error) 178X (Fixed Disk error) 1800 (No more hardware interrupt available for PCI adapter) 1801 (No room for PCI option ROM) 1802 (No more I/O space available for PCI adapter) 1803 (No more memory (above 1MB for PCI adapter) FRU/Action 1. Cable 1. System Board 1. Fixed Disk Cables 2. Run Configuration/Setup 3. Fixed Disk Adapter, if fitted 4. Fixed Disk Drive 5. System Board 1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter, if fitted 4. Fixed Disk Drive 5. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 212 Netfinity Server HMM