IBM 86645RY Hardware Maintenance Manual - Page 228

NDIS 4.0 Windows NT driver messages, The explanation and recommended action are

Page 228 highlights

PCNTND-21 The adapter failed the checksum test. Explanation: The driver cannot find an Ethernet controller. Action: Verify that the Ethernet controller is enabled. (See "PCI Slot/Device Information" on page 35.) If the Ethernet controller is enabled, go to "General checkout" on page 6 to run the diagnostic programs. PCNTND-23 WARNING: PCNET IRQ found = xx Explanation: The interrupt request (IRQ) setting (xx) in the PROTOCOL.INI file does not match the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI file or change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the PCI Slot/Device Information selection of the Advanced Setup menu in the Configuration/Setup Utility program. (See "PCI Slot/Device Information" on page 35.) PCNTND-24 WARNING: PCNET IRQ does not match PROTOCOL.INI. Explanation: The interrupt request (IRQ) setting in the PROTOCOL.INI file does not match the hardware IRQ setting. Action: Remove the IRQ setting from the PROTOCOL.INI file or change the IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the PCI Slot/Device Information selection of the Advanced Setup menu in the Configuration/Setup Utility program. (See "PCI Slot/Device Information" on page 35.) PCNTND-25 PCI scan specified, PCI bus not found! Explanation: The driver cannot locate the PCI bus. Action: Run the diagnostic programs (go to "General checkout" on page 6). PCNTND-29 WARNING: DMA number is not necessary for PCI device. Explanation: The Ethernet controller does not require a DMA setting. Action: Remove the DMA setting in the PROTOCOL.INI file. PCNTND-33 PCNET device with specified IOBASE is already in use. Explanation: The specified I/O address number is already in use by another Ethernet controller or device. Action: Remove the I/O address setting in the PROTOCOL.INI file. NDIS 4.0 (Windows NT) driver messages: This section contains the error messages for the NDIS 4.0 drivers. The explanation and recommended action are included with each message. PermaNet(tm) Server: No Secondary Adapter Found. Grouping Mode is disabled. Explanation: The failover option requires an adapter that is compatible with the device driver of the Ethernet controller on the system board. No such adapter was found. Action: Make sure the correct adapter is installed. . PermaNet(tm) Server: Problem Occurs on the Primary Adapter. Switching over to the Secondary Adapter. Explanation: The system detected a problem with the primary Ethernet connection and has transferred all network traffic to the secondary Ethernet controller. Action: Identify the cause of the failure on the primary Ethernet connection. Restoring the operational state of the primary connection will cause the network traffic to automatically transfer to the primary Ethernet controller. PermaNet(tm) Server: Switching back to Primary Adapter. Explanation: The primary Ethernet connection is now operating correctly. Network traffic will automatically transfer to the primary Ethernet controller. Action: None needed, message is for information only. . 220 Netfinity Server HMM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276

PCNTND-21
The adapter failed the checksum test.
Explanation:
The driver cannot find an Ethernet controller.
Action:
Verify that the Ethernet controller is enabled.
(See “PCI Slot/Device
Information” on page
35.) If the Ethernet controller is enabled, go to “General
checkout” on page
6 to run the diagnostic programs.
PCNTND-23
WARNING:
PCNET IRQ found
=
xx
Explanation:
The interrupt request (IRQ) setting (
xx
) in the PROTOCOL.INI
file does not match the hardware IRQ setting.
Action:
Remove the IRQ setting from the PROTOCOL.INI file or change the
IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the
PCI Slot/Device Information
selection of the Advanced Setup menu in the
Configuration/Setup Utility program.
(See “PCI Slot/Device Information” on
page 35.)
PCNTND-24
WARNING:
PCNET IRQ does not match PROTOCOL.INI.
Explanation:
The interrupt request (IRQ) setting in the PROTOCOL.INI file
does not match the hardware IRQ setting.
Action:
Remove the IRQ setting from the PROTOCOL.INI file or change the
IRQ setting in the PROTOCOL.INI file to match the IRQ setting shown in the
PCI Slot/Device Information
selection of the Advanced Setup menu in the
Configuration/Setup Utility program.
(See “PCI Slot/Device Information” on
page 35.)
PCNTND-25
PCI scan specified, PCI bus not found!
Explanation:
The driver cannot locate the PCI bus.
Action:
Run the diagnostic programs (go to “General checkout” on page
6).
PCNTND-29
WARNING:
DMA number is not necessary for PCI
device.
Explanation:
The Ethernet controller does not require a DMA setting.
Action:
Remove the DMA setting in the PROTOCOL.INI file.
PCNTND-33
PCNET device with specified IOBASE is already in use.
Explanation:
The specified I/O address number is already in use by another
Ethernet controller or device.
Action:
Remove the I/O address setting in the PROTOCOL.INI file.
NDIS 4.0 (Windows NT) driver messages:
This section contains the error messages for the NDIS 4.0
drivers.
The explanation and recommended action are
included with each message.
PermaNet(tm) Server: No Secondary Adapter Found. Grouping Mode is
disabled.
Explanation:
The failover option requires an adapter that is compatible with
the device driver of the Ethernet controller on the system board.
No such
adapter was found.
Action:
Make sure the correct adapter is installed.
.
PermaNet(tm) Server: Problem Occurs on the Primary Adapter. Switching
over to the Secondary Adapter.
Explanation:
The system detected a problem with the primary Ethernet
connection and has transferred all network traffic to the secondary Ethernet
controller.
Action:
Identify the cause of the failure on the primary Ethernet connection.
Restoring the operational state of the primary connection will cause the
network traffic to automatically transfer to the primary Ethernet controller.
PermaNet(tm) Server: Switching back to Primary Adapter.
Explanation:
The primary Ethernet connection is now operating correctly.
Network traffic will automatically transfer to the primary Ethernet controller.
Action:
None needed, message is for information only.
.
220
Netfinity Server HMM