Approximate heat output in British Thermal Units Btu, Heat Output, Acoustical Noise Emissions Values
View all IBM 86645RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
- +12 V dc line: 17.2 A Heat Output Approximate heat output in British Thermal Units (Btu) per hour: - Minimum configuration: 683 Btu (200 watts) - Maximum configuration: 2048 Btu (600 watts) Acoustical Noise Emissions Values Sound power, idling: 6.6 bel maximum Sound power, operating: 6.8 bel maximum Sound pressure, operating: 67 dBa maximum 56 Netfinity Server HMM
–
+12 V dc line:
17.2 A
Heat Output
±
Approximate heat output in British Thermal Units (Btu)
per hour:
–
Minimum configuration:
683 Btu
(200 watts)
–
Maximum configuration:
2048 Btu
(600 watts)
Acoustical Noise Emissions Values
±
Sound power, idling:
6.6 bel maximum
±
Sound power, operating:
6.8 bel maximum
±
Sound pressure, operating:
67 dBa maximum
56
Netfinity Server HMM