Failed Tape Drive Test, drive with SCSI ID YY.
![]() |
View all IBM 86645RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 214 highlights
Error Code/Symptom 217-XXX-002 (Failed BIOS Fixed Disk test) Note If RAID is configured, the fixed disk number refers to the RAID logical drive. 217-XXX-003 (Failed BIOS Fixed Disk test) Note If RAID is configured, the fixed disk number refers to the RAID logical drive. 217-XXX-004 (Failed BIOS Fixed Disk test) Note If RAID is configured, the fixed disk number refers to the RAID logical drive. 217-XXX-005 (Failed BIOS Fixed Disk test) Note If RAID is configured, the fixed disk number refers to the RAID logical drive. 264-XXX-0YY (Failed Tape Drive Test) FRU/Action 1. Fixed Disk 3 1. Fixed Disk 4 1. Fixed Disk 5 1. Fixed Disk 6 1. Tape Cartridge, if user executed the Read/Write Tape Drive test (failure code of XXX=256). 2. SCSI or power cable connected to the tape drive with SCSI ID YY. 3. Tape Drive with SCSI ID YY. Refer to the Help and Service Information appendix of the tape drive's User Guide. 4. System board or SCSI controller. Run SCSI Controller Diagnostics to determine if the SCSI bus is functioning properly. 206 Netfinity Server HMM