Icom ID-880H Instruction Manual - Page 127

Scan resume condition

Page 127 highlights

SCAN OPERATION 8 Scan resume condition D Scan pause timer The scan pauses when receiving signals according to the scan pause time. It can be set from 2 to 20 sec. or unlimited. q Enter "PAUSE" in the SCAN set mode. MENU ¶ SCAN ¶ PAUSE (p. 123) (Push [MENU ]), (rotate [DIAL], then push [ ](MONI).) w Rotate [DIAL] to select the desired scan pausing time from 2-20 sec. (2 sec. steps) or "HOLD." • "2SEC"-"20SEC": Scan pauses for 2-20 sec. while receiving a signal. • "HOLD" : Scan pauses on a received a signal until it disappears. e Push [ ](MONI) to return to the SCAN set mode. r Push [MENU ] to return to frequency indication. D Scan resume timer The scan restarts after the signal disappears according to the resume time. It can be set from 0-5 sec. or unlimited. q Enter "RESUME" in the SCAN set mode. MENU ¶ SCAN ¶ RESUME (p. 123) (Push [MENU ]), (rotate [DIAL], then push [ ](MONI).) w Rotate [DIAL] to select the desired scan resume time from 0-5 sec. (1 sec. steps) and "HOLD." • "0SEC" : Scan restarts immediately after the signal dis- appears. • "1SEC"-"5SEC": Scan restarts 1-5 sec. after the signal disap- pears. • "HOLD" : Scan remains paused on the received signal according to the scan pause timer even if it dis- appears. Rotate [DIAL] to resume manually. e Push [ ](MONI) to return to the SCAN set mode. r Push [MENU ] to return to frequency indication. Scan resume timer must be set shorter than the scan pause timer, otherwise this timer does not activate. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 109

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196

109
8
SCAN OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
±
Scan resume condition
D
Scan pause timer
The scan pauses when receiving signals according to the
scan pause time. It can be set from 2 to 20 sec. or unlimited.
q
Enter “PAUSE” in the SCAN set mode.
w
Rotate
[DIAL]
to select the desired scan pausing time
from 2–20 sec. (2 sec. steps) or “HOLD.”
• “2SEC”–“20SEC” :
Scan pauses for 2–20 sec. while receiving a
signal.
• “HOLD”
:
Scan pauses on a received a signal until it
disappears.
e
Push
[
]
(MONI) to return to the SCAN set mode.
r
Push
[MENU
]
to return to frequency indication.
D
Scan resume timer
The scan restarts after the signal disappears according to the
resume time. It can be set from 0–5 sec. or unlimited.
q
Enter “RESUME” in the SCAN set mode.
MENU
SCAN
RESUME
(p. 123)
(Push
[MENU
]
), (rotate
[DIAL]
, then push
[
]
(MONI).)
w
Rotate
[DIAL]
to select the desired scan resume time from
0–5 sec. (1 sec. steps) and “HOLD.”
• “0SEC”
:
Scan restarts immediately after the signal dis-
appears.
• “1SEC”–“5SEC”:
Scan restarts 1–5 sec. after the signal disap-
pears.
• “HOLD”
:
Scan remains paused on the received signal
according to the scan pause timer even if it dis-
appears. Rotate
[DIAL]
to resume manually.
e
Push
[
]
(MONI) to return to the SCAN set mode.
r
Push
[MENU
]
to return to frequency indication.
Scan resume timer must be set shorter than the scan
pause timer, otherwise this timer does not activate.
MENU
SCAN
PAUSE
(p. 123)
(Push
[MENU
]
), (rotate
[DIAL]
, then push
[
]
(MONI).)