Pentax PZ-1p PZ-1p Manual - Page 44
Pentax PZ-1p Manual
View all Pentax PZ-1p manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
* When the main switch is set at [USER), the multisegment metering mode is selected automatically and no other metering modes can be used. * When a lens with no lens information contacts (lenses made before M lenses) is used, use either the center-weighted metering or the spot metering. The milti-segment metering mode cannot be set. If the main switch is set at .-USER:!. only the center weighted metering can be used. However, the spot metering can be used if USER-SET] function is selected at the main switch is at `USEW position. See page 74. n MULTI( 8 )-SEGMENT METERING This camera incorporates a high-precision eightsegment TTL metering system. Light values are measured in eight segments within the image field, enabling an optimal exposure to be made under a variety of lighting conditions. With conventional averaged metering systems, underexposure of the subject results from the brightness of the background affecting the overall metering. With multi(8)-segment metering, the camera records the brightness in eight zones within the image field and uses these measurements to choose an exposure that will not underexposed the subject. The multi(8)-segment metering system also calculates exposure values for a scene to automatically compensate for high-contrast and other difficult lighting conditions. Even a beginner can achieve excellent results with ease.