TP-Link T2600G-18TSTL-SG3216 T2600G-18TSUN V1 Configuration Guide - Page 391
Current Link Event, Link Monitoring Config, Apply, select a Link Event type to be con d.
View all TP-Link T2600G-18TSTL-SG3216 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 391 highlights
Configuring OAM Ethernet OAM Configurations Follow these steps to configure Link Monitoring: 1) In the Current Link Event section, select a Link Event type to be configured. Current Link Event Select Link Event type. The following options are provided: Symbol Period Error: A Symbol Period Error event occurs if the number of symbol errors exceeds the defined threshold within a specific period of time. Frame Error: A Frame Error event occurs if the number of frame errors exceeds the defined threshold within a specific period of time. Frame Period Error: A Frame Period Error event occurs if the number of frame errors in specific number of received frames exceeds the defined threshold. Frame Seconds Error: A Frame Seconds Error event occurs if the number of error frame seconds exceeds the threshold within a specific period of time. A second is called an error frame second if error frames occur in the second. 3) In the Link Monitoring Config section, select one or more ports, and configure the threshold and period for the selected link event. Threshold Specify the threshold for the selected link event. Threshold (Error Symbol): If you select Symbol Period Error as the link event type, specify the threshold of received symbol errors within a specific period of time. The valid values are from 1 to 4294967295 error frames, and the default value is 1 error frame. Threshold (Error Frame): If you select Frame Error or Frame Period Error as the link event type, specify the threshold of frame errors within a specific period of time or in specific number of received frames. The valid values are from 1 to 4294967295 error frames, and the default value is 1 error frame. Threshold (Error Seconds): If you select Frame Seconds Error as the link event type, specify the threshold of error frame seconds. The valid values are from 1 to 900 error frame seconds, and the default value is 1 error frame second. Window Specify the period for the selected link event. Window (100ms): If you select Symbol Period Error, Frame Error or Frame Seconds Error as the link event type, specify the period time in 100ms, in which if the received errors exceed the threshold, a link event will be generated. For Symbol Period Error and Frame Error, the valid values are from 10*100 to 600*100 ms, and the default value is 10*100 ms. For Frame Seconds Error, the valid values are from 100*100 to 9000*100 ms, and the default value is 600*100 ms. Window (Frames): If you select Frame Period Error as the link event type, specify the number of frames, in which if the frame errors exceed the threshold, a link event will be generated. The valid values are from 148810 to 89286000 frames, and the default value is 1488100 frames. Notify 4) Click Apply. Enable or disable the port to report the Link Event. By default, all types of the Link Events can be reported. Configuration Guide 361