Set ID Format DEC/HEX for Motorola or AFS/DEC for EDACS

Page 51 highlights

available, instead of block 1. If you assign Block 0 as 14, you would not see another prompt because 14 uses all available blocks. Priority ID Scan (no EDACS SCAT/P25-1Tr) allows you to use Priority Scan with IDs. 1. Scroll to 'Priority ID Scan' and press E/ . 2. Scroll to 'On' or 'Off' and press E/ . Set Status Bit (Motorola only) sets how your scanner works with status bits (also called S-bits), letting you control how the scanner interprets and displays Motorola talkgroup IDs. The default setting is ignore. 1. Scroll to 'Set Status Bit' and press E/ . 2. Scroll to one of two settings and press E/ to save and exit. Yes - the scanner treats all received ID's as unique ID's. Ignore - the scanner rounds all received ID's down to the next interval of 16. Set End Code (Motorola only) sets how the scanner handles the transmission end code sent by most Motorola systems. 1. Scroll to 'Set End Code' and press E/ . 2. Scroll to one of three settings and press E/ . Analog - The scanner recognizes only analog end transmission codes. Analog+Digital - The scanner recognizes both analog and digital end codes. Ignore - The scanner waits for the carrier to drop before leaving a channel. Emergency Alert (Motorola/EDACS only) sets how your scanner handles IDs that have the emergency flag set. The default setting is off. 1. Scroll to 'Emergency Alert' and press E/ . 2. Scroll to 'Set Alert Tone' and press E/ . 3. At 'Set Tone' scroll to the alert (Alert 1-9 or Off) and press E/ . 4. At 'Set Level' scroll to 'Level 1-15 or Auto' (the scanner sets the alert beep to the master volume level) and press E/ . 5. Scroll to 'Set Alert Light' and press E/ . 6. Scroll to Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White and press E/ . 7. At 'Set Pattern' scroll to On, Slow Blink, or Fast Blink and press E/ . 8. Press MENU to return. Set ID Format (DEC/HEX for Motorola or AFS/DEC for EDACS) sets the ID format for the system. 1. Scroll to 'Set ID Format' and press E/ . 2. (Motorola) Scroll to 'Decimal Format' or 'Hex Format' and press E/ to save and exit. 3. (EDACS) Scroll to 'AFS Format' or 'Decimal Format' and press E/ to save and exit. Set Record enables the REC jack for all channels or marked channels in the system or off. 1. Scroll to 'Set Record' and press E/ . 2. Scroll to one of 3 settings and press E/ to save and exit. All Channel - The scanner sends the audio for all channels in the system to the REC jack, regardless of the channel's record option setting. 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

47
available, instead of block 1. If you assign Block 0 as 14, you would not see another prompt
because 14 uses all available blocks.
Priority ID Scan (no EDACS SCAT/P25-1Tr)
allows you to use Priority Scan with IDs.
1.
Scroll to ‘Priority ID Scan’ and press
E/
°
2.
Scroll to ‘On’ or ‘Off’ and press
E/
.
Set Status Bit (Motorola only)
sets how your scanner works with status bits (also called S-bits),
letting you control how the scanner interprets and displays Motorola talkgroup IDs. The default
setting is ignore.
1.
Scroll to ‘Set Status Bit’ and press
E/
°
2.
Scroll to one of two settings and press
E/
to save and exit.
Yes
- the scanner treats all received ID’s as unique ID’s.
Ignore
- the scanner rounds all received ID’s down to the next interval of 16.
Set End Code (Motorola only)
sets how the scanner handles the transmission end code sent by
most Motorola systems.
1.
Scroll to ‘Set End Code’ and press
E/
°
2.
Scroll to one of three settings and press
E/
.
Analog
- The scanner recognizes only analog end transmission codes.
Analog+Digital
- The scanner recognizes both analog and digital end codes.
Ignore
- The scanner waits for the carrier to drop before leaving a channel.
Emergency Alert (Motorola/EDACS only)
sets how your scanner handles IDs that have the
emergency flag set. The default setting is off.
1.
Scroll to ‘Emergency Alert’ and press
E/
°
2.
Scroll to ‘Set Alert Tone’ and press
E/
.
3.
At ‘Set Tone’ scroll to the alert (Alert 1-9 or Off) and press
E/
.
4.
At ‘Set Level’ scroll to ‘Level 1-15 or Auto’ (the scanner sets the alert beep to the master
volume level) and press
E/
.
5.
Scroll to ‘Set Alert Light’ and press
E/
.
6.
Scroll to Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White and press
E/
.
7.
At ‘Set Pattern’ scroll to On, Slow Blink, or Fast Blink and press
E/
.
8.
Press
MENU
to return.
Set ID Format (DEC/HEX for Motorola or AFS/DEC for EDACS)
sets the ID format for the
system.
1.
Scroll to ‘Set ID Format’ and press
E/
°
2.
(Motorola) Scroll to ‘Decimal Format’ or ‘Hex Format’ and press
E/
to save and exit.
3.
(EDACS) Scroll to ‘AFS Format’ or ‘Decimal Format’ and press E/
to save and exit.
Set Record
enables the REC jack for all channels or marked channels in the system or off.
1.
Scroll to ‘Set Record’ and press
E/
°
2.
Scroll to one of 3 settings and press
E/
to save and exit.
All Channel
- The scanner sends the audio for all channels in the system to the REC
jack, regardless of the channel’s record option setting.