Uniden BCD996P2 English Manual - Page 93

Set CC Bands, Set CC Override, Close Call Only, Using Close Call, Modes, Set CC Alert, Set CC Mode,

Page 93 highlights

Set CC Bands Set CC Alert Set CC Override Set CC Mode Close Call Only CC Auto Store Using Close Call Modes Managing Close Call Hits Hits with Scan Set CC Bands allows you select the Close Call bands to be searched or auto stored. 1. Scroll to 'Set CC Bands' and press E/ . 2. Scroll to each band and press E/ to toggle on or off. 3. Press MENU to return. VHF Low 1 - Band 1 - 25-54MHz VHF Low 2 - Band 2 - 54-108 MHz Air Band-Band 3 - 108-137 MHz VHF High1 - Band 4 - 137-225 MHz VHF High2 - Band 5 - 225-320 MHz UHF-Band 6 - 320-512 MHz 800MHz+-Band 7 - 758-960, 1240-1300 MHz Set CC Alert allows you to set an alert tone, alert light, and controls the pause for Close Call when you receive a hit. 1. Scroll to 'Set CC Alert' and press E/ . 2. Scroll to 'Set Alert Tone' and press E/ . 3. At 'Set Tone' scroll to the alert (Alert 1-9 or Off) and press E/ . 4. At 'Set Level' scroll to 'Level 1-15 or Auto' (the scanner sets the alert beep to the master volume level) and press E/ . 5. Scroll to 'Set Alert Light' and press E/ . 6. Scroll to Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White and press E/ . 7. At 'Set Pattern' scroll to On, Slow Blink, or Fast Blink and press E/ . 8. Press MENU to return. 9. Scroll to 'Set CC Pause' and press E/ . 10. Scroll to the number of seconds (3, 5, 10, 15, 30, 45, 60, secs. or Infinite) you want the scanner to pause on the CC hit and press E/ . Set CC Override allows you select how the Close Call feature works while scanning or searching. This setting has no effect in 'Close Call Only' mode. 1. Scroll to 'Set CC Override' press E/ . 2. Scroll to On or Off and press E/ to save and exit. With this feature On, when the scanner detects a Close Call signal while scanning, the scanner overrides the current audio with the Close Call hit. 'Close Call' appears for the length of time set in Close Call Pause (or until the signal is lost if longer). With this feature Off, when the scanner detects a Close Call signal while scanning, the scanner does not override the current audio. 'Close Call' appears for the length of time set in Close Call Pause. (only if it's still there). 89

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

89
Set CC Bands
Set CC Override
Close Call Only
Using Close Call
Modes
Set CC Alert
Set CC Mode
CC Auto Store
Managing Close Call
Hits
Hits with Scan
Set CC Bands
allows you select the Close Call bands to be searched or auto stored.
1.
Scroll to ‘Set CC Bands’ and press
E/
.
2.
Scroll to each band and press
E/
to toggle on or off.
3.
Press
MENU
to return.
VHF Low 1 - Band 1 - 25-54MHz
VHF Low 2 - Band 2 - 54-108 MHz
Air Band-Band 3 - 108-137 MHz
VHF High1 - Band 4 - 137-225 MHz
VHF High2 - Band 5 - 225-320 MHz
UHF-Band 6 - 320-512 MHz
800MHz+-Band 7 - 758-960, 1240-1300 MHz
Set CC Alert
allows you to set an alert tone, alert light, and controls the pause for Close Call
when you receive a hit.
1.
Scroll to ‘Set CC Alert’ and press
E/
.
2.
Scroll to ‘Set Alert Tone’ and press
E/
.
3.
At ‘Set Tone’ scroll to the alert (Alert 1-9 or Off) and press
E/
.
4.
At ‘Set Level’ scroll to ‘Level 1-15 or Auto’ (the scanner sets the alert beep to the master
volume level) and press
E/
.
5.
Scroll to ‘Set Alert Light’ and press
E/
.
6.
Scroll to Off, Blue, Red, Magenta, Green, Cyan, Yellow, or White and press
E/
.
7.
At ‘Set Pattern’ scroll to On, Slow Blink, or Fast Blink and press
E/
.
8.
Press
MENU
to return.
9.
Scroll to ‘Set CC Pause’ and press
E/
.
10.
Scroll to the number of seconds (3, 5, 10, 15, 30, 45, 60, secs. or Infinite) you want the
scanner to pause on the CC hit and press
E/
.
Set CC Override
allows you select how the Close Call feature works while scanning or searching.
This setting has no effect in ‘Close Call Only’ mode.
1.
Scroll to ‘Set CC Override’ press
E/
.
2.
Scroll to On or Off and press
E/
to save and exit.
With this feature On, when the scanner detects a Close Call signal while scanning, the scanner
overrides the current audio with the Close Call hit.
‘Close Call’ appears for the length of time set in Close Call Pause (or until the signal is lost if
longer).
With this feature Off, when the scanner detects a Close Call signal while scanning, the scanner
does not override the current audio.
‘Close Call’ appears for the length of time set in Close Call Pause. (only if it’s still there).