Uniden BCD996P2 English Manual - Page 94

Close Call Auto Store, Using Close Call Modes

Page 94 highlights

Set Close Call Mode selects the Close Call mode when scanning or searching. You can also toggle these modes by pressing SQ in scan mode. 1. Scroll to 'Set CC Mode' and press E/ . 2. Scroll to 1 of 3 modes and press E/ to save and exit. Off - Close Call is turned off. CC DND - Close Call checks for frequencies every two seconds between transmissions. PRI - Close Call checks for frequencies every two seconds. Close Call Only this setting puts the scanner in Close Call Only mode. You can also do this by pressing and holding SQ in scan mode. You will see activity in the 7 bands in the display. Bands with a * (asterisk) under them are turned off. 1. Scroll to 'Close Call Only' and press E/ . 2. Press SCAN/SEARCH to exit. CLOSE CALL AUTO STORE Allows you to automatically store Close Call hits into channels. If you turn this feature on, the scanner mutes, starts Close Call Only mode, and stores any Close Call hits from the bands selected in 'Set CC Bands' up to the maximum you specified in the 'Max Auto Store' setting. The scanner looks for active frequencies within the range(s) and 'Search and Store' appears in the display. When the scanner finds an active transmission, it checks to see if the frequency has already been stored in the system. If the frequency has already been stored, the scanner continues to search. If the frequency has not been stored, it stores the frequency into a (created) system called 'Close Call' and a (created) group named 'Found Channels' then resumes searching. This new system and group have the same options as any conventional system/group and can be edited the same way. 1. Scroll to 'CC Auto Store' and press E/ . You will see activity in the enabled bands in the display. Bands with a * (asterisk) under them are turned off. 'Limit Reached' will appear in the display when the 'Max Auto Store' value is reached. 2. Press SCAN/SEARCH to exit or HOLD to go to 'Close Call Only' mode. USING CLOSE CALL MODES To Start Close Call Only Mode, press and hold SQ( ). To Use Close Call while Scanning or Searching, press SQ( ) to toggle Close Call Priority, Close Call DND, or Off. 90

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

90
Set Close Call Mode
selects the Close Call mode when scanning or searching. You can also
toggle these modes by pressing
SQ
in scan mode.
1.
Scroll to ‘Set CC Mode’ and press
E/
.
2.
Scroll to 1 of 3 modes and press
E/
to save and exit.
Off
- Close Call is turned off.
CC DND
- Close Call checks for frequencies every two seconds between transmissions.
PRI
- Close Call checks for frequencies every two seconds.
Close Call Only t
his setting puts the scanner in Close Call Only mode. You can also do this by
pressing and holding
SQ
in scan mode. You will see activity in the 7 bands in the display. Bands
with a * (asterisk) under them are turned off.
1.
Scroll to ‘Close Call Only’ and press
E/
.
2.
Press
SCAN/SEARCH
to exit.
CLOSE CALL AUTO STORE
Allows you to automatically store Close Call hits into channels. If you turn this feature on, the
scanner mutes, starts Close Call Only mode, and stores any Close Call hits from the bands
selected in ‘Set CC Bands’ up to the maximum you specified in the ‘Max Auto Store’ setting.
The scanner looks for active frequencies within the range(s) and ‘Search and Store’ appears
in the display. When the scanner finds an active transmission, it checks to see if the frequency
has already been stored in the system. If the frequency has already been stored, the scanner
continues to search. If the frequency has not been stored, it stores the frequency into a (created)
system called ‘Close Call’ and a (created) group named ‘Found Channels’ then resumes
searching. This new system and group have the same options as any conventional system/group
and can be edited the same way.
1.
Scroll to ‘CC Auto Store’ and press
E/
.
You will see activity in the enabled bands in the display. Bands with a * (asterisk) under them
are turned off.
‘Limit Reached’ will appear in the display when the ‘Max Auto Store’ value is reached.
2.
Press
SCAN/SEARCH
to exit or
HOLD
to go to ‘Close Call Only’ mode.
USING CLOSE CALL MODES
To Start Close Call Only Mode, press and hold
SQ
(
).
To Use Close Call while Scanning or Searching, press
SQ
(
) to toggle Close Call Priority, Close
Call DND, or Off.