Brother International IntelliFax-3550 Service Manual - Page 100

In those countries where no dial tone detection function is supported, setting these selectors to 1

Page 100 highlights

WSW06 (PAUSE key setting and 2nd dial tone detection) Selector No. Function 1 | PAUSE key setting and 2nd dial tone detection 3 Setting and Specifications No. 1 2 3 0 0 0 : No pause 0 0 1 : 3.5 sec. WAIT 0 1 0 : 7 sec. WAIT 0 1 1 : 10.5 sec. WAIT 1 0 0 : 14 sec. WAIT 1 0 1 : 17.5 sec. WAIT 1 1 0 : 2nd dial tone detection only in pulse dialing (DP) system 1 1 1 : 2nd dial tone detection both in DP and pushbutton (PB) dialing systems 4 | Detection of international tone 6 No. 4 5 6 000 : 001 : 010 : 011 : 100 : 101 : 110 : 111 : 50 ms 210 ms 500 ms 800 ms 900 ms 1.5 sec. 2.0 sec. 2.5 sec. 7 No. of 2nd dial tone detection times 8 2nd dial tone interrupt detecting time 0: Once 0: 30 ms 1: Twice 1: 50 ms NOTE: Selectors 4 through 8 are not applicable in those countries where no dial tone detection is supported, e.g., U.S.A. q Selectors 1 through 3: PAUSE key setting and 2nd dial tone detection Selectors 123 0 0 0 No WAIT is inserted even if the PAUSE key is pressed. 001 010 011 100 101 Pressing the PAUSE key inserts WAIT in pulse dialing, as defined in the above table. If the PAUSE key is pressed repeatedly, the equipment beeps a refusal sound and refuses the entry. In hook-up dialing, however, the equipment allows repeated pressing with an acceptance sound, but inserts WAIT only for the first pressing. 110 111 Each time the PAUSE key is pressed, the equipment detects a 2nd dial tone. If no 2nd dial tone is inputted within the specified time, the equipment disconnects the line in automatic dialing, or it starts transmitting the dial signal if given after depression of the PAUSE key in hook-up dialing. (In those countries where no dial tone detection function is supported, setting these selectors to "1, 1, 0" or "1, 1, 1" inserts a WAIT of 3.5 seconds.) V - 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

V –
18
WSW06
(PAUSE key setting and 2nd dial tone detection)
Function
Selector
No.
Setting and Specifications
2nd dial tone interrupt detecting
time
1
|
3
4
|
6
8
7
0:
Once
1:
Twice
0:
30 ms
1:
50 ms
Detection of international tone
No.
1
2
3
0
0
0
:
No pause
0
0
1
:
3.5 sec. WAIT
0
1
0
:
7 sec. WAIT
0
1
1
:
10.5 sec. WAIT
1
0
0
:
14 sec. WAIT
1
0
1
:
17.5 sec. WAIT
1
1
0
:
2nd dial tone detection
only in pulse dialing
(DP) system
1
1
1
:
2nd dial tone detection
both in DP and push-
button (PB) dialing
systems
No.
4
5
6
0
0
0
:
50 ms
0
0
1
:
210 ms
0
1
0
:
500 ms
0
1
1
:
800 ms
1
0
0
:
900 ms
1
0
1
:
1.5 sec.
1
1
0
:
2.0 sec.
1
1
1
:
2.5 sec.
NOTE:
Selectors 4 through 8 are not applicable in those countries where no dial tone detec-
tion is supported, e.g., U.S.A.
Selectors 1 through 3:
PAUSE key setting and 2nd dial tone detection
Selectors
1
2
3
1
1
0
1
1
1
Each time the PAUSE key is pressed, the equipment detects a 2nd
dial tone.
If no 2nd dial tone is inputted within the specified time, the equipment
disconnects the line in automatic dialing, or it starts transmitting the
dial signal if given after depression of the PAUSE key in hook-up
dialing.
(In those countries where no dial tone detection function is supported,
setting these selectors to "1, 1, 0" or "1, 1, 1" inserts a WAIT of 3.5
seconds.)
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
Pressing the PAUSE key inserts WAIT in pulse dialing, as defined in
the above table.
If the PAUSE key is pressed repeatedly, the equipment beeps a refusal
sound and refuses the entry.
In hook-up dialing, however, the equipment allows repeated pressing
with an acceptance sound, but inserts WAIT only for the first pressing.
0
0
0
No WAIT is inserted even if the PAUSE key is pressed.
PAUSE key setting and 2nd dial
tone detection
No. of 2nd dial tone detection times