Detailed Description for the Firmware Switches, WSW01, Dial pulse setting, Selectors 1 and 2
View all Brother International IntelliFax-3550 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
s Detailed Description for the Firmware Switches WSW01 (Dial pulse setting) Selector No. Function 1 Dial pulse generation mode 2 3 Break time length in pulse 4 dialing Setting and Specifications No. 1 2 00 : 01 : 10 : 11 : N N+1 10-N N No. 3 4 00 : 01 : 10 : 11 : 60 ms 67 ms 40 ms (for 16 PPS) 64 ms (at 106-ms intervals) 5 Inter-digit pause 6 Switching between pulse (DP) 7 and tone (PB) dialing, by the function switch Default dialing mode, pulse 8 (DP) or tone (PB) dialing No. 5 6 00 : 01 : 10 : 11 : 800 ms 850 ms 950 ms 600 ms 0: Yes 1: No 0: PB 1: DP q Selectors 1 and 2: Dial pulse generation mode These selectors set the number of pulses to be generated in pulse dialing. N: Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.) N + 1: Dialing "N" generates "N + 1" pulses. 10 - N: Dialing "N" generates "10 - N" pulses. q Selectors 3 and 4: Break time length in pulse dialing These selectors set the break time length in pulse dialing. (Example: If "1", "2", and "3" are dialled when N is set by selectors 1 and 2.) Break time length set by selectors 3 and 4 "1" "2" "3" q Selectors 5 and 6: Inter-digit pause These selectors set the inter-digit pause in pulse dialing. (Example: If "1", "2", and "3" are dialled when N is set by selectors 1 and 2.) "1" "2" V - 12 "3" Inter-digit pause set by selectors 5 and 6