Brother International IntelliFax-3550 Service Manual - Page 92

Firmware Switch Setting and Printout, ware switches may not be applicable in some versions.

Page 92 highlights

3.6 Firmware Switch Setting and Printout [ A ] Firmware switch setting s Function The facsimile equipment incorporates the following firmware switch functions (WSW01 through WSW34) which may be activated with the procedures using the control panel keys and buttons. The firmware switches have been set at the factory in conformity to the communications standards and codes of each country. Do not disturb them unless necessary. Some firmware switches may not be applicable in some versions. The firmware switch data list indicates "Not used." for those inapplicable switches. WSW No. WSW01 WSW02 WSW03 WSW04 WSW05 WSW06 WSW07 WSW08 WSW09 WSW10 WSW11 WSW12 WSW13 WSW14 WSW15 WSW16 WSW17 WSW18 WSW19 WSW20 WSW21 WSW22 WSW23 WSW24 WSW25 WSW26 WSW27 WSW28 WSW29 WSW30 WSW31 WSW32 WSW33 WSW34 Firmware Switches (WSW01 through WSW34) Function Dial pulse setting Tone signal setting PABX mode setting TRANSFER facility setting 1st dial tone and busy tone detection PAUSE key setting and 2nd dial tone detection Dial tone setting 1 Dial tone setting 2 Protocol definition 1 Protocol definition 2 Busy tone setting Signal detection condition setting Modem setting AUTO ANS facility setting REDIAL facility setting Function setting 1 Function setting 2 Function setting 3 Transmission speed setting Overseas communications mode setting TAD setting 1 Communications setting 1 Communications setting 2 TAD setting 2 TAD setting 3 Function setting 4 Function setting 5 Function setting 6 Function setting 7 Function setting 8 Function setting 9 Function setting 10 Function setting 11 Function setting 12 Reference Page V-12 V-13 V-14 V-15 V-16 V-18 V-20 V-21 V-22 V-23 V-24 V-25 V-26 V-27 V-28 V-29 V-30 V-31 V-32 V-33 V-34 V-34 V-35 V-36 V-37 V-38 V-39 V-40 V-41 V-42 V-43 V-43 V-44 V-45 V - 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

V –
10
WSW No.
Function
Reference Page
WSW01
Dial pulse setting
V
-12
WSW02
Tone signal setting
V
-13
WSW03
PABX mode setting
V
-14
WSW04
TRANSFER facility setting
V
-15
WSW05
1st dial tone and busy tone detection
V
-16
WSW06
PAUSE key setting and 2nd dial tone detection
V
-18
WSW07
Dial tone setting 1
V
-20
WSW08
Dial tone setting 2
V
-21
WSW09
Protocol definition 1
V
-22
WSW10
Protocol definition 2
V
-23
WSW11
Busy tone setting
V
-24
WSW12
Signal detection condition setting
V
-25
WSW13
Modem setting
V
-26
WSW14
AUTO ANS facility setting
V
-27
WSW15
REDIAL facility setting
V
-28
WSW16
Function setting 1
V
-29
WSW17
Function setting 2
V
-30
WSW18
Function setting 3
V
-31
WSW19
Transmission speed setting
V
-32
WSW20
Overseas communications mode setting
V
-33
WSW21
TAD setting 1
V
-34
WSW22
Communications setting 1
V
-34
WSW23
Communications setting 2
V
-35
WSW24
TAD setting 2
V
-36
WSW25
TAD setting 3
V
-37
WSW26
Function setting 4
V
-38
WSW27
Function setting 5
V
-39
WSW28
Function setting 6
V
-40
WSW29
Function setting 7
V
-41
WSW30
Function setting 8
V
-42
WSW31
Function setting 9
V
-43
WSW32
Function setting 10
V
-43
WSW33
Function setting 11
V
-44
WSW34
Function setting 12
V
-45
3.6
Firmware Switch Setting and Printout
[ A ]
Firmware switch setting
Function
The facsimile equipment incorporates the following firmware switch functions (WSW01
through WSW34) which may be activated with the procedures using the control panel keys
and buttons.
The firmware switches have been set at the factory in conformity to the communications
standards and codes of each country.
Do not disturb them unless necessary.
Some firm-
ware switches may not be applicable in some versions.
The firmware switch data list indi-
cates "Not used." for those inapplicable switches.
Firmware Switches (WSW01 through WSW34)