Brother International IntelliFax-3550 Service Manual - Page 113
XWSW18, Selectors 7 and 8
View all Brother International IntelliFax-3550 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
WSW18 (Function setting 3) Selector No. 1 Function Not used. 2 Detection enabled time for CNG 3 and no tone 4 5 Not used. 6 Registration of station ID Setting and Specifications No. 2 3 00 01 10 11 40 sec. 0 sec. (No detection) 5 sec. 80 sec. 0: Permitted 1: Prohibited 7 Tone sound monitoring 8 No. 7 8 0X : 10 : 11 : No monitoring Up to phase B at the calling station only All transmission phases both at the calling and called stations q Selectors 2 and 3: Detection enabled time for CNG and no tone After the line is connected via the external telephone, the equipment can detect a CNG signal or no tone for the time length specified by these selectors. q Selector 6: Registration of station ID Setting this selector to "0" permits the registration of a station ID for Austrian and Czech versions. q Selectors 7 and 8: Tone sound monitoring These selectors set the monitoring specifications of the tone sound inputted from the line. V - 31