IBM 8862 Hardware Maintenance Manual - Page 106

xxx-00n

Page 106 highlights

Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are replaceable by the customer and which components must be replaced by an IBM field service technician. Error code/symptom FRU/action 020-xxx-000 (Failed PCI Interface test) 1. PCI switch card assembly 2. I/O board 020-xxx-001 (Failed Hot-Swap Slot 1 PCI 1. PCI hot-swap latch assembly Latch test) 2. PCI switch card assembly 020-xxx-002 (Failed Hot-Swap Slot 2 PCI 1. PCI hot-swap latch assembly Latch test) 2. PCI switch card assembly 020-xxx-003 (Failed Hot-Swap Slot 3 PCI 1. PCI hot-swap latch assembly Latch test) 2. PCI switch card assembly 020-xxx-004 (Failed Hot-Swap Slot 4 PCI 1. PCI hot-swap latch assembly Latch test) 2. PCI switch card assembly 020-xxx-005 (Failed Hot-Swap Slot 5 PCI 1. PCI hot-swap latch assembly Latch test) 2. PCI switch card assembly 020-xxx-006 (Failed Hot-Swap Slot 6 PCI 1. PCI hot-swap latch assembly Latch test) 2. PCI switch card assembly 030-xxx-000 (Failed Internal SCSI interface test) 1. Make sure SCSI is not enabled, rerun test. 2. I/O board. 030-xxx-00n (Failed SCSI test on PCI slot v Adapter in slot n n. Check system error log before replacing a FRU.) 035-002-0nn (ServeRAID interface timeout) 1. ServeRAID controller may not be configured properly. Obtain the basic and extended configuration status bytes and see the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. ServeRAID controller. 035-253-0nn (ServeRAID controller 0nn initialization failure; 0nn = the controller number) 1. ServeRAID controller may not be configured properly. Obtain the basic and extended configuration status bytes and see the ServeRAID Hardware Maintenance Manual for more information. 2. Cable. 3. SCSI backplane. 4. ServeRAID controller. 035-253-s99 (RAID adapter initialization failure) 1. ServeRAID adapter 2. SCSI cable 035-254-0nn (Setup error - unable to allocate memory to run test.) v Check system resources. 035-255-0nn (Internal Error) 1. SCSI backplane 2. Cable 035-260-0nn (System to controller interface failure) 1. ServeRAID adapter 2. I/O board 96 IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Note:
See
Chapter
7,
“Parts
listing,
Types
8861,
8862,”
on
page
139
to
determine
which
components
are
replaceable
by
the
customer
and
which
components
must
be
replaced
by
an
IBM
field
service
technician.
Error
code/symptom
FRU/action
020-xxx-000
(Failed
PCI
Interface
test)
1.
PCI
switch
card
assembly
2.
I/O
board
020-xxx-001
(Failed
Hot-Swap
Slot
1
PCI
Latch
test)
1.
PCI
hot-swap
latch
assembly
2.
PCI
switch
card
assembly
020-xxx-002
(Failed
Hot-Swap
Slot
2
PCI
Latch
test)
1.
PCI
hot-swap
latch
assembly
2.
PCI
switch
card
assembly
020-xxx-003
(Failed
Hot-Swap
Slot
3
PCI
Latch
test)
1.
PCI
hot-swap
latch
assembly
2.
PCI
switch
card
assembly
020-xxx-004
(Failed
Hot-Swap
Slot
4
PCI
Latch
test)
1.
PCI
hot-swap
latch
assembly
2.
PCI
switch
card
assembly
020-xxx-005
(Failed
Hot-Swap
Slot
5
PCI
Latch
test)
1.
PCI
hot-swap
latch
assembly
2.
PCI
switch
card
assembly
020-xxx-006
(Failed
Hot-Swap
Slot
6
PCI
Latch
test)
1.
PCI
hot-swap
latch
assembly
2.
PCI
switch
card
assembly
030-xxx-000
(Failed
Internal
SCSI
interface
test)
1.
Make
sure
SCSI
is
not
enabled,
rerun
test.
2.
I/O
board.
030-xxx-00n
(Failed
SCSI
test
on
PCI
slot
n.
Check
system
error
log
before
replacing
a
FRU.)
v
Adapter
in
slot
n
035-002-0nn
(ServeRAID
interface
timeout)
1.
ServeRAID
controller
may
not
be
configured
properly.
Obtain
the
basic
and
extended
configuration
status
bytes
and
see
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Cable.
3.
SCSI
backplane.
4.
ServeRAID
controller.
035-253-0nn
(ServeRAID
controller
0nn
initialization
failure;
0nn
=
the
controller
number)
1.
ServeRAID
controller
may
not
be
configured
properly.
Obtain
the
basic
and
extended
configuration
status
bytes
and
see
the
ServeRAID
Hardware
Maintenance
Manual
for
more
information.
2.
Cable.
3.
SCSI
backplane.
4.
ServeRAID
controller.
035-253-s99
(RAID
adapter
initialization
failure)
1.
ServeRAID
adapter
2.
SCSI
cable
035-254-0nn
(Setup
error
-
unable
to
allocate
memory
to
run
test.)
v
Check
system
resources.
035-255-0nn
(Internal
Error)
1.
SCSI
backplane
2.
Cable
035-260-0nn
(System
to
controller
interface
failure)
1.
ServeRAID
adapter
2.
I/O
board
96
IBM
xSeries
365
Types
8861,
8862:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide