IBM 8862 Hardware Maintenance Manual - Page 88
Power-supply, structure
UPC - 000435172679
View all IBM 8862 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
a. The tabs on the bottom of the insulators sit in the holes in the bottom of the metal section of the bracket. b. The tabs on the top of the insulators engage the plastic retainer section of the bracket. Power-supply structure This section contains information about removing and replacing the power-supply structure. Note: v v v Read "Installation guidelines" on page 29. Read "Safety information" on page 147. Read "Handling static-sensitive devices" on page 30. Complete the following steps to remove the power-supply structure: 1. Turn off the server and all peripheral devices; then, disconnect all power cords and external cables. 2. Remove the top cover (see "Removing the cover and bezel" on page 32). 3. Remove the fans (see "Replacing a hot-swap fan" on page 55). 4. Remove the memory cassette (see "Installing a microprocessor" on page 44). 5. Remove the power supplies (see "Installing a hot-swap power supply" on page 51). 6. Pull the two blue latches ( 1 ) on the power-supply structure toward the front of the server; the structure will disengage from the chassis. Latches Handle 7. Grasp the handle in the middle of the structure and rotate the back of the structure up ( 2 ), allowing the structure to pivot at the end closest to the front of the chassis. 8. Slide the structure toward the rear of the server ( 3 ), disengaging the tabs on the structure from the slots in the server ( 4 ). 78 IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide