IBM 8862 Hardware Maintenance Manual - Page 110

Hardware, Maintenance, Manual

Page 110 highlights

Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are replaceable by the customer and which components must be replaced by an IBM field service technician. Error code/symptom FRU/action 166-201-114 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 2) Expansion Enclosure. 166-201-115 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 3) Expansion Enclosure. 166-201-116 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 4) Expansion Enclosure. 166-201-117 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 5) Expansion Enclosure. 166-201-118 (ISMP indicates I2C errors on v See Hardware Maintenance Manual for IBM RXE-100 Remote RXE bus PCI_B slot 6) Expansion Enclosure. 166-260-000 (ASM restart failure) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry. 2. Remote Supervisor Adapter. 166-342-000 (System Management BIST indicates failed tests) 1. Disconnect all server and option power cords from server, wait 30 seconds, reconnect, and retry. 2. Remote Supervisor Adapter. 166-400-000 (ISMP Self Test Result failed 1. Disconnect all server and option power cords from server, wait tests: xxx) where xxx=flash, ROM, or RAM 30 seconds, reconnect, and retry. 2. (Re)flash ISMP with latest firmware level. 3. I/O board. 166-400-100 (DMC Self Test Result failed 1. Disconnect all server and option power cords from server, wait tests: xxx) where xxx=flash, ROM, or RAM 30 seconds, reconnect, and retry. 2. (Re)flash ISMP on RXE with latest firmware level. 3. RXE backplane. 180-197-000 (SCSI ASPI driver not installed) 1. Remove RAID adapter, if installed, and rerun test. 2. SCSI backplane. 3. I/O board. 4. Microprocessor tray assembly. 180-361-003 (Failed Fan LED test) 1. Fan 2. I/O board 180-xxx-000 (Diagnostics LED failure) v Run diagnostic LED test for failing LED. 180-xxx-001 (Failed Front LED Panel test) 1. Operator information panel cable 2. Operator information panel 3. I/O board 4. Microprocessor tray assembly 180-xxx-002 (Failed Diagnostics LED Panel test) 1. Operator information panel cable 2. Operator information panel 3. I/O board 4. Microprocessor tray assembly 100 IBM xSeries 365 Types 8861, 8862: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Note:
See
Chapter
7,
“Parts
listing,
Types
8861,
8862,”
on
page
139
to
determine
which
components
are
replaceable
by
the
customer
and
which
components
must
be
replaced
by
an
IBM
field
service
technician.
Error
code/symptom
FRU/action
166-201-114
(ISMP
indicates
I2C
errors
on
RXE
bus
PCI_B
slot
2)
v
See
Hardware
Maintenance
Manual
for
IBM
RXE-100
Remote
Expansion
Enclosure.
166-201-115
(ISMP
indicates
I2C
errors
on
RXE
bus
PCI_B
slot
3)
v
See
Hardware
Maintenance
Manual
for
IBM
RXE-100
Remote
Expansion
Enclosure.
166-201-116
(ISMP
indicates
I2C
errors
on
RXE
bus
PCI_B
slot
4)
v
See
Hardware
Maintenance
Manual
for
IBM
RXE-100
Remote
Expansion
Enclosure.
166-201-117
(ISMP
indicates
I2C
errors
on
RXE
bus
PCI_B
slot
5)
v
See
Hardware
Maintenance
Manual
for
IBM
RXE-100
Remote
Expansion
Enclosure.
166-201-118
(ISMP
indicates
I2C
errors
on
RXE
bus
PCI_B
slot
6)
v
See
Hardware
Maintenance
Manual
for
IBM
RXE-100
Remote
Expansion
Enclosure.
166-260-000
(ASM
restart
failure)
1.
Disconnect
all
server
and
option
power
cords
from
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Remote
Supervisor
Adapter.
166-342-000
(System
Management
BIST
indicates
failed
tests)
1.
Disconnect
all
server
and
option
power
cords
from
server,
wait
30
seconds,
reconnect,
and
retry.
2.
Remote
Supervisor
Adapter.
166-400-000
(ISMP
Self
Test
Result
failed
tests:
xxx)
where
xxx=flash,
ROM,
or
RAM
1.
Disconnect
all
server
and
option
power
cords
from
server,
wait
30
seconds,
reconnect,
and
retry.
2.
(Re)flash
ISMP
with
latest
firmware
level.
3.
I/O
board.
166-400-100
(DMC
Self
Test
Result
failed
tests:
xxx)
where
xxx=flash,
ROM,
or
RAM
1.
Disconnect
all
server
and
option
power
cords
from
server,
wait
30
seconds,
reconnect,
and
retry.
2.
(Re)flash
ISMP
on
RXE
with
latest
firmware
level.
3.
RXE
backplane.
180-197-000
(SCSI
ASPI
driver
not
installed)
1.
Remove
RAID
adapter,
if
installed,
and
rerun
test.
2.
SCSI
backplane.
3.
I/O
board.
4.
Microprocessor
tray
assembly.
180-361-003
(Failed
Fan
LED
test)
1.
Fan
2.
I/O
board
180-xxx-000
(Diagnostics
LED
failure)
v
Run
diagnostic
LED
test
for
failing
LED.
180-xxx-001
(Failed
Front
LED
Panel
test)
1.
Operator
information
panel
cable
2.
Operator
information
panel
3.
I/O
board
4.
Microprocessor
tray
assembly
180-xxx-002
(Failed
Diagnostics
LED
Panel
test)
1.
Operator
information
panel
cable
2.
Operator
information
panel
3.
I/O
board
4.
Microprocessor
tray
assembly
100
IBM
xSeries
365
Types
8861,
8862:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide