IBM 8862 Hardware Maintenance Manual - Page 121
cable/card.
UPC - 000435172679
View all IBM 8862 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
Note: See Chapter 7, "Parts listing, Types 8861, 8862," on page 139 to determine which components are replaceable by the customer and which components must be replaced by an IBM field service technician. Service Processor message FRU/action Fan X Failure (X of 1-6 = individual fans 1 1. Verify no obstacles are blocking or inserted into the fan or through 6; X of 7=power supply 1; X of 8=power power supply. supply 2.) 2. Check the physical connection and verify fan or power supply is properly seated. 3. Replace component X: a. Where X = a number from 1 through 6, replace fan X. b. Where X = 7 or 8, replace power supply X. Fan X not detected (X of 1-6 = individual fans 1 through 6; X of 7=power supply 1; X of 8=power supply 2.) 1. Verify no obstacles are blocking or inserted into the fan or power supply. 2. Check the physical connection and verify fan or power supply is properly seated. 3. Replace component X: a. Where X = a number from 1 through 6, replace fan X. b. Where X = 7 or 8, replace power supply X. Fan X Outside Recommended Speed (X of 1-6 = individual fans 1 through 6; X of 7=power supply 1; X of 8=power supply 2.) 1. Verify no obstacles are blocking or inserted into the fan or power supply. 2. Check the physical connection and verify fan or power supply is properly seated. 3. Replace component X: a. Where X = a number from 1 through 6, replace fan X. b. Where X = 7 or 8, replace power supply X. Front Panel is not plugged in 1. Verify operator panel cables are properly connected (verify LED activity). 2. Replace operator information panel. Hard Drive X Fault 1. Run diagnostics. 2. Hard disk drive. 3. ServeRAID adapter. 4. SCSI backplane. Hard drive X removal detected v Re-insert hard disk drive X and restart server. Hostname set to by user v Information only Hot plug card is not plugged in 1. Verify PCI cabling. 2. Failing hot plug cable/card. Integrated Systems Management Processor 1. Remove ac power from the server and restart the server encountered failures upon starting 2. Run diagnostics. Internal Error CPU X Fault v Microprocessor X Internal SCSI cable is not plugged in 1. Verify SCSI cables are properly connected. 2. SCSI backplane. Invalid CPU configuration v Verify that microprocessors have been installed in the correct order (see "Installing a microprocessor" on page 44). Invalid Fan configuration v Replace any missing or failed fans. Chapter 6. Symptom-to-FRU index 111