Kyocera FS-1128MFP Service Manual - Page 32

Setting ECM transmission, Setting ECM reception - redial fax

Page 32 highlights

2JN-2 Section Fax Item No. U612 U620 U625 Content of maintenance item Setting system 3 Selecting if auto reduction in the auxiliary direction is to be performed Setting the automatic printing of the protocol list Setting how trailing edge margins are detected Setting the remote switching mode Setting the transmission system 1 Setting the auto redialing interval Setting the number of times of auto redialing U630 U631 U632 U633 U634 U640 U641 Setting communication control 1 Setting the communication starting speed Setting the reception speed Setting the waiting period to prevent echo problems at the sender Setting the waiting period to prevent echo problems at the receiver Setting communication control 2 Setting ECM transmission Setting ECM reception Setting the frequency of the CED signal Setting communication control 3 Setting the DIS signal to 4 bytes Setting the short protocol transmission Setting the reception of a short protocol transmission Setting the CNG detection times in the fax/telephone auto select mode Setting communication control 4 Enabling/disabling V.34 communication Setting the V.34 symbol speed (3429 Hz) Setting the number of times of DIS signal reception Setting the reference for RTN signal output Setting communication control 5 Setting communication time 1 One-shot detection time for remote switching Continuous detection time for remote switching Setting communication time 2 Setting the T0 time-out time Setting the T1 time-out time Setting the T2 time-out time Setting the Ta time-out time Setting the Tb1 time-out time Setting the Tb2 time-out time Setting the Tc time-out time Setting the Td time-out time U650 Setting modem 1 Setting the G3 transmission cable equalizer Setting the G3 reception cable equalizer Setting the modem detection level Initial setting* ON OFF ON ONE*2 3 (120 V)*2 2 (220-240 V)*2 2 (120 V)*2 3 (220-240 V)*2 14400bps/V17*2 14400bps*2 300*2 75*2 ON*2 ON*2 2100*2 OFF*2 ON*2 ON*2 2TIME*2 ON*2 ON*2 ONCE*2 15%*2 0*2 7*2 80*2 56*2 36*2 69*2 30*2 20*2 80*2 60*2 9 (120 V)*2 6 (220-240 V)*2 0dB*2 0dB*2 43dBm*2 *: Factory initial setting, *1: The item initialized for executing U021, *2: The item initialized for executing U600 1-3-4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

2JN-2
1-3-4
Fax
U612
Setting system 3
Selecting if auto reduction in the auxiliary direction is to be per-
formed
Setting the automatic printing of the protocol list
Setting how trailing edge margins are detected
ON
OFF
ON
U620
Setting the remote switching mode
ONE
*2
U625
Setting the transmission system 1
Setting the auto redialing interval
Setting the number of times of auto redialing
3 (120 V)
*2
2 (220-240 V)
*2
2 (120 V)
*2
3 (220-240 V)
*2
U630
Setting communication control 1
Setting the communication starting speed
Setting the reception speed
Setting the waiting period to prevent echo problems at the sender
Setting the waiting period to prevent echo problems at the receiver
14400bps/V17
*2
14400bps
*2
300
*2
75
*2
U631
Setting communication control 2
Setting ECM transmission
Setting ECM reception
Setting the frequency of the CED signal
ON
*2
ON
*2
2100
*2
U632
Setting communication control 3
Setting the DIS signal to 4 bytes
Setting the short protocol transmission
Setting the reception of a short protocol transmission
Setting the CNG detection times in the fax/telephone auto select mode
OFF
*2
ON
*2
ON
*2
2TIME
*2
U633
Setting communication control 4
Enabling/disabling V.34 communication
Setting the V.34 symbol speed (3429 Hz)
Setting the number of times of DIS signal reception
Setting the reference for RTN signal output
ON
*2
ON
*2
ONCE
*2
15%
*2
U634
Setting communication control 5
0
*2
U640
Setting communication time 1
One-shot detection time for remote switching
Continuous detection time for remote switching
7
*2
80
*2
U641
Setting communication time 2
Setting the T0 time-out time
Setting the T1 time-out time
Setting the T2 time-out time
Setting the Ta time-out time
Setting the Tb1 time-out time
Setting the Tb2 time-out time
Setting the Tc time-out time
Setting the Td time-out time
56
*2
36
*2
69
*2
30
*2
20
*2
80
*2
60
*2
9 (120 V)
*2
6 (220-240 V)
*2
U650
Setting modem 1
Setting the G3 transmission cable equalizer
Setting the G3 reception cable equalizer
Setting the modem detection level
0dB
*2
0dB
*2
43dBm
*2
Section
Item
No.
Content of maintenance item
Initial
setting*
*: Factory initial setting, *1: The item initialized for executing U021, *2: The item initialized for executing U600