Kyocera FS-1128MFP Service Manual - Page 74

Setting the target, Description, Purpose, Method, Setting: [ADJUST ORIGINAL], Maintenance, item No

Page 74 highlights

2JN Maintenance item No. Description U425 Setting the target Description Enters the lab values that is indicated on the back of the chart (P/N: 302FZ56990) used for adjustment. Purpose Performs data input in order to correct for differences in originals during automatic adjustment. Method 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description N875 Setting the N875 patch for the original for adjustment N475 Setting the N475 patch for the original for adjustment N125 Setting the N125 patch for the original for adjustment CYAN Setting the cyan patch for the original for adjustment MAGENTA Setting the magenta patch for the original for adjustment YELLOW Setting the yellow patch for the original for adjustment RED Setting the red patch for the original for adjustment GREEN Setting the green patch for the original for adjustment BLUE Setting the blue patch for the original for adjustment ADJUST ORIGINAL Setting the main and auxiliary scanning directions 3. Select the item to be set using the cursor up/down keys. Display Description L Setting the L value a Setting the a value b Setting the b value Setting range 0.0 to 100.0 -200.0 to 200.0 -200.0 to 200.0 4. Enters the value that is indicated on the back of the chart using the cursor left/right keys or numeric keys. 5. Press the start key. The value is set. 6. To return to the screen for selecting an item, press the stop key. Setting: [ADJUST ORIGINAL] 1. Measure the distance from the left edge to the black belt (a) of the original at A, B and C. Measurement procedure 1) Measure the distance from the edge to the black belt (a) of the original at A (30 mm from the leading edge), B (148.5 mm from the leading edge) and C (267 mm from the leading edge), respectively. 2) Apply the following formula for the values obtained: ((A + C) / 2 + B) / 2 2. Enter the values solved using the cursor left/right keys or numeric keys in [MAIN]. 3. Press the start key. The value is set. 4. Measure the distance from the leading edge to the black belt (b) of the original at D, E and F. Measurement procedure 1) Measure the distance from the edge to the black belt (b) of the original at D (35 mm from the left edge), E (110 mm from the left edge) and F (185 mm from the left edge), respectively. 2) Apply the following formula for the values obtained: ((D + F) / 2 + E) / 2 5. Enter the values solved using the cursor left/right keys or numeric keys in [SUB LEAD]. 6. Press the start key. The value is set. 7. Measure the length (G) from the edge of the black belt (b) to edge of the black belt (c) of the original. 8. Enter the measured value using the cursor left/right keys or numeric keys in [SUB TAIL]. 9. Press the start key. The value is set. 10. To return to the screen for selecting an item, press the stop key. 1-3-46

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

2JN
1-3-46
U425
Setting the target
Description
Enters the lab values that is indicated on the back of the chart (P/N: 302FZ56990) used for adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1.
Press the start key.
2.
Select the item to be set using the cursor up/down keys.
3.
Select the item to be set using the cursor up/down keys.
4.
Enters the value that is indicated on the back of the chart using the cursor left/right keys or numeric
keys.
5.
Press the start key. The value is set.
6.
To return to the screen for selecting an item, press the stop key.
Setting: [ADJUST ORIGINAL]
1.
Measure the distance from the left edge to the black belt (a) of the original at A, B and C.
Measurement procedure
1) Measure the distance from the edge to the black belt (a) of the original at A (30 mm from the leading
edge), B (148.5 mm from the leading edge) and C (267 mm from the leading edge), respectively.
2) Apply the following formula for the values obtained: ((A + C) / 2 + B) / 2
2.
Enter the values solved using the cursor left/right keys or numeric keys in [MAIN].
3.
Press the start key. The value is set.
4.
Measure the distance from the leading edge to the black belt (b) of the original at D, E and F.
Measurement procedure
1) Measure the distance from the edge to the black belt (b) of the original at D (35 mm from the left
edge), E (110 mm from the left edge) and F (185 mm from the left edge), respectively.
2) Apply the following formula for the values obtained: ((D + F) / 2 + E) / 2
5.
Enter the values solved using the cursor left/right keys or numeric keys in [SUB LEAD].
6.
Press the start key. The value is set.
7.
Measure the length (G) from the edge of the black belt (b) to edge of the black belt (c) of the original.
8.
Enter the measured value using the cursor left/right keys or numeric keys in [SUB TAIL].
9.
Press the start key. The value is set.
10.To return to the screen for selecting an item, press the stop key.
Maintenance
item No.
Description
Display
Description
N875
Setting the N875 patch for the original for adjustment
N475
Setting the N475 patch for the original for adjustment
N125
Setting the N125 patch for the original for adjustment
CYAN
Setting the cyan patch for the original for adjustment
MAGENTA
Setting the magenta patch for the original for adjustment
YELLOW
Setting the yellow patch for the original for adjustment
RED
Setting the red patch for the original for adjustment
GREEN
Setting the green patch for the original for adjustment
BLUE
Setting the blue patch for the original for adjustment
ADJUST ORIGINAL
Setting the main and auxiliary scanning directions
Display
Description
Setting range
L
Setting the L value
0.0 to 100.0
a
Setting the a value
-200.0 to 200.0
b
Setting the b value
-200.0 to 200.0