Kyocera FS-1128MFP Service Manual - Page 94

List of Software Switches of Which the Setting Can Be Changed, <Communication control procedure&gt

Page 94 highlights

2JN Maintenance item No. Description U699 Setting the software switches Description Sets the software switches on the FAX PWB individually. Purpose To change the setting when a problem such as split output of received originals occurs. Since the communication performance is largely affected, normally this setting need not be changed. Method 1. Press the start key. 2. Press [SW No.]. 3. Enter the desired software switch number (3 digits) using the numeric keys and press the enter key. 4. Use numeric keys 7 to 0 to switch each bit between 0 and 1. 5. Press the start key to set the value. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed. List of Software Switches of Which the Setting Can Be Changed No. Bit Item 39 21 Declaration of reception size in automatic paper source selection for fax No. Bit Item 31 2 Automatic reception level adjustment (V. 17) 1 Automatic reception level adjustment (V. 29) 0 Automatic reception level adjustment (V. 27ter) 36 7654 Coding format in transmission 3210 Coding format in reception 37 5 33600 bps/V34 4 31200 bps/V34 3 28800 bps/V34 2 26400 bps/V34 1 24000 bps/V34 0 21600 bps/V34 38 7 19200 bps/V34 6 16800 bps/V34 5 14400 bps/V34 4 12000 bps/V34 3 9600 bps/V34 2 7200 bps/V34 1 4800 bps/V34 0 2400 bps/V34 41 3 FSK detection in V.8 42 2 FIF length in transmission of more than 4 times of DIS/DTC signal 0 Automatic reception level adjustment (V. 33) 43 76543210 Adjustment width in automatic reception level adjustment 1-3-66

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

2JN
1-3-66
U699
Setting the software switches
Description
Sets the software switches on the FAX PWB individually.
Purpose
To change the setting when a problem such as split output of received originals occurs.
Since the communication performance is largely affected, normally this setting need not be changed.
Method
1.
Press the start key.
2.
Press [SW No.].
3.
Enter the desired software switch number (3 digits) using the numeric keys and press the enter key.
4.
Use numeric keys 7 to 0 to switch each bit between 0 and 1.
5.
Press the start key to set the value.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
List of Software Switches of Which the Setting Can Be Changed
<System setting>
<Communication control procedure>
Maintenance
item No.
Description
No.
Bit
Item
39
21
Declaration of reception size in automatic paper source selection for fax
No.
Bit
Item
31
2
Automatic reception level adjustment (V. 17)
1
Automatic reception level adjustment (V. 29)
0
Automatic reception level adjustment (V. 27ter)
36
7654
Coding format in transmission
3210
Coding format in reception
37
5
33600 bps/V34
4
31200 bps/V34
3
28800 bps/V34
2
26400 bps/V34
1
24000 bps/V34
0
21600 bps/V34
38
7
19200 bps/V34
6
16800 bps/V34
5
14400 bps/V34
4
12000 bps/V34
3
9600 bps/V34
2
7200 bps/V34
1
4800 bps/V34
0
2400 bps/V34
41
3
FSK detection in V.8
42
2
FIF length in transmission of more than 4 times of DIS/DTC signal
0
Automatic reception level adjustment (V. 33)
43
76543210
Adjustment width in automatic reception level adjustment