Page 37 highlights
2JN-2 Maintenance item No. Description U001 Exiting the maintenance mode Description Exits the maintenance mode and returns to the normal copy mode. Purpose To exit the maintenance mode. Method Press the start key. The normal copy mode is entered. U002 Setting the factory default data Description Restores the machine conditions to the factory default settings. Purpose To move the mirror frame of the scanner to the position for transport (position in which the frame can be fixed). Method 1. Press the start key. 2. Select [MODE1(ALL)] using the cursor up/down keys. 3. Press the start key. The mirror frame of the scanner returns to the position for transport. 4. Turn the main power switch off and on. U004 U019 An error code is displayed in case of an initialization error. Refer to the table of the error codes on P.1-3-10. When errors occurred, turn main power switch off then on, and execute initialization using maintenance item U002. Displaying the machine number Description Displays the machine number. Purpose To check the machine number. Method Press the start key. The currently machine number is displayed. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed. Displaying the ROM version Description Displays the part number of the ROM fitted to each PWB. Purpose To check the part number or to decide, if the newest version of ROM is installed. Method 1. Press the start key. The ROM version are displayed. 2. Change the screen using the cursor up/down keys. Display Description MAIN Control PWB ROM MMI Operation panel PWB ROM ENGINE Engine ROM ENGINE BOOT Engine booting CASS 2 Optional paper feeder main PWB ROM CASS 3 Optional paper feeder main PWB ROM SCANNER Scanner PWB ROM SCANNER BOOT Scanner PWB booting OPTION LANGUAGE Optional language ROM FAX BOOT FAX PWB booting FAX APL FAX PWB APL FAX IPL FAX PWB IPL Completion Press the stop key. The screen for selecting a maintenance item No. is displayed. 1-3-9