Kyocera FS-1128MFP Service Manual - Page 83

Setting ECM reception, Sets ECM transmission. - cost per page

Page 83 highlights

2JN Maintenance item No. Description U630 (cont.) Setting the waiting period to prevent echo problems at the receiver Sets the period before an NSF, CSI or DIS signal is sent after a CED signal is received. Used when problems occur due to echoes at the receiver. 1. Select the setting using the cursor up/down keys. Display Description 500 Sends an NSF, CSI or DIS 500 ms after receiving a CED. 75 Sends an NSF, CSI or DIS 75 ms after receiving a CED. U631 Initial setting: 75 2. Press the start key. The setting is set. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed. Setting communication control 2 Description Makes settings regarding fax transmission. Start 1. Press the start key. 2. Select the item to be set using the cursor up/down keys. Display Description ECM TX Sets ECM transmission. ECM RX Sets ECM reception. CED FREQ. Sets the frequency of the CED signal. Setting ECM transmission To be set to OFF when reduction of transmission costs is of higher priority than image quality. This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line. 1. Select the setting using the cursor up/down keys. Display Description ON ECM transmission is enabled. OFF ECM transmission is disabled. Initial setting: ON 2. Press the start key. The setting is set. Setting ECM reception To be set to OFF when reduction of transmission costs is of higher priority than image quality. This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line. 1. Select the setting using the cursor up/down keys. Display Description ON ECM reception is enabled. OFF ECM reception is disabled. Initial setting: ON 2. Press the start key. The setting is set. Setting the frequency of the CED signal Sets the frequency of the CED signal. Used as one of the measures to improve transmission performance for international communications. 1. Select the setting using the cursor up/down keys. Display Description 2100 2100 Hz 1100 1100 Hz Initial setting: 2100 2. Press the start key. The setting is set. Completion Press the stop key. The screen for selecting a maintenance item No. is displayed. 1-3-55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252

2JN
1-3-55
U630
(cont.)
Setting the waiting period to prevent echo problems at the receiver
Sets the period before an NSF, CSI or DIS signal is sent after a CED signal is received. Used when problems
occur due to echoes at the receiver.
1.
Select the setting using the cursor up/down keys.
Initial setting: 75
2.
Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U631
Setting communication control 2
Description
Makes settings regarding fax transmission.
Start
1.
Press the start key.
2.
Select the item to be set using the cursor up/down keys.
Setting ECM transmission
To be set to OFF when reduction of transmission costs is of higher priority than image quality.
This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line.
1.
Select the setting using the cursor up/down keys.
Initial setting: ON
2.
Press the start key. The setting is set.
Setting ECM reception
To be set to OFF when reduction of transmission costs is of higher priority than image quality.
This should not be set to OFF when connecting to the IP (Internet Protocol) telephone line.
1.
Select the setting using the cursor up/down keys.
Initial setting: ON
2.
Press the start key. The setting is set.
Setting the frequency of the CED signal
Sets the frequency of the CED signal. Used as one of the measures to improve transmission performance for
international communications.
1.
Select the setting using the cursor up/down keys.
Initial setting: 2100
2.
Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
500
Sends an NSF, CSI or DIS 500 ms after receiving a CED.
75
Sends an NSF, CSI or DIS 75 ms after receiving a CED.
Display
Description
ECM TX
Sets ECM transmission.
ECM RX
Sets ECM reception.
CED FREQ.
Sets the frequency of the CED signal.
Display
Description
ON
ECM transmission is enabled.
OFF
ECM transmission is disabled.
Display
Description
ON
ECM reception is enabled.
OFF
ECM reception is disabled.
Display
Description
2100
2100 Hz
1100
1100 Hz