Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 122
If the ProLiant Storage System, Check SCSI cables. If
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 122 highlights
Diagnostics and Troubleshooting 3-25 Table 3-2 POST Error Messages continued Error Code Audible Beeps 1777-Slot X Drive None Array - ProLiant Drive Storage Enclosure Problem Detected (followed by one or more of the following): SCSI Port Y: Cooling Fan Malfunction Detected SCSI Port Y: Overheated Condition Detected SCSI Port Y: Side-Panel must be Closed to Prevent Overheating SCSI Port Y: Redundant Power Supply Malfunction Detected SCSI Port Y: Wide SCSI Transfer Failed SCSI Port Y: Interrupt Signal Inoperative (RESUME = F1 KEY) 1778-Drive Array None resuming Automatic Data Recovery process 1779-Slot X Drive None Array - Replacement drive(s) detected OR previously failed drive(s) now operational: Port Y: SCSI ID Z: Restore data from backup if replacement drive X has been installed. 1780-Disk 0 Failure None 1781-Disk 1 Failure None Probable Source of Problem Temperature violation detected. Recommended Action Check cooling fan operation by placing hand over fan. Verify internal plenum cooling fan in tower servers or storage systems is operational. If fan is not operating, check for obstructions and verify all internal connections. Replace unit side panel if removed. If the ProLiant Storage System power LED is amber instead of green, this indicates a redundant power supply failure. Check SCSI cables. If the message indicates to check SCSI cables, verify your cabling against the diagrams in your Compaq Smart Array Controller user guide. If the routing is correct, replace cables on the specified port until the POST message is eliminated. This message appears whenever a controller reset or power cycle occurs while Automatic Data Recovery is in progress. Intermittent drive failure and/or possible loss of data detected. No action necessary. If this message displays and drive X has not been replaced, this indicates an intermittent drive failure. This message also displays immediately following drive replacement whenever data must be restored from backup. Hard drive/format error detected. Hard drive/format error detected. Run Compaq Diagnostics. Replace failed assembly as indicated. Run Compaq Diagnostics. Replace failed assembly as indicated. continued