Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 156
Place the drives back in their original, Restart the server, and complete
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 156 highlights
Diagnostics and Troubleshooting 3-59 Table 3-16 ADU Diagnostic Messages continued Message Description Swapped cables or Configuration error detected. One or more drive locations were changed while an expand operation was in progress. A drive rearrangement was attempted while an expand operation was running. This is an unsupported operation. SOLUTION: Power down system then move drives back to their original location. Power on system and wait for the expand operation to complete before attempting a drive rearrangement. Swapped cables or Configuration error detected. One or more physical drives were moved, causing a configuration that is not supported. An unsupported drive arrangement was attempted. SOLUTION: Power down system then move drives back to their original location. Recommended Action 1. Power down the server. 2. Place the drives back in their original locations. 3. Restart the server, and complete the expand operation. 4. Move the drives to their new locations after the expand operation is completed. Move all drives back to their original locations, and refer to your user documentation for supported configurations. continued