Removal and Replacement Procedures 2-23 5. If the plastic switch cover is installed, remove it by prying outward on the upper or lower catch with a 4-mm flatblade screwdriver. Then pull the cover off the switch . 1 2 Figure 2-17. Removing the plastic switch cover 6. Press in on the release tabs on the Power On/Standby switch assembly. From behind the unit, push the assembly out of the front of the server . 3 4 3 Figure 2-18. Removing the Power On/Standby switch and LED Reverse steps 1 through 6 to replace the Power On/Standby switch and LED.
Removal and Replacement Procedures
2-23
5.
If the plastic switch cover is installed, remove it by prying outward on the upper or lower
catch
with a 4-mm flatblade screwdriver. Then pull the cover off the switch
.
1
2
Figure 2-17.
Removing the plastic switch cover
6.
Press in on the release tabs
on the Power On/Standby switch assembly. From behind the
unit, push the assembly out of the front of the server
.
3
4
3
Figure 2-18.
Removing the Power On/Standby switch and LED
Reverse steps 1 through 6 to replace the Power On/Standby switch and LED.