Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 194
Table 4-6, System Interlock LED Indicators on I/O Board
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 194 highlights
Connectors, Switches, and Status Indicators 4-9 Table 4-6 System Interlock LED Indicators on I/O Board Possible Affected Components to Check Interlock Power (Aux 5V) Power Fail System Interlock None (system operational) If the server does not power up: 1. Reinsert the power supply. ON OFF OFF 2. Place the Power On/Standby switch to ON. 3. Verify that the power supply status LED blinks green for 10 to 20 seconds and then is solid green when the server powers up. 4. If the Power Supply Status LED stays dark (does not blink), verify that the I/O board power cable is connected at the I/O board and the power backplane. Power switch cables ON OFF ON I/O-to-processor board connection Processor board components Processor Power Modules ON ON OFF Power supplies Power cables Note: If the System Interlock LED is on, check the processor board LEDs to isolate the failure point.