Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 144
Run the System Configuration Utility
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 144 highlights
Diagnostics and Troubleshooting 3-47 Table 3-16 ADU Diagnostic Messages continued Message Description Accelerator status: Valid data found at reset Valid data was found in posted-write memory at reinitialization. Data will be flushed to disk. Accelerator status: Warranty alert Catastrophic problem with array accelerator board. Refer to other messages on Diagnostics screen for exact meaning of this message. Adapter/NVRAM ID mismatch EISA nonvolatile RAM has an ID for a different controller from the one physically present in the slot. Array accelerator battery pack X not fully charged Battery is not fully charged. Array accelerator battery pack X below reference voltage (recharging) Board in use by expand operation Board not attached Configuration signature is zero Configuration signature mismatch Controller communication failure occurred Controller detected. NVRAM configuration not present Controller firmware needs upgrading Battery pack on array accelerator is below required voltage levels. Array accelerator memory is in use by Expand operation. Array controller configured for use with array accelerator board, but one is not attached. ADU detected that nonvolatile RAM contains a configuration signature of zero. Old versions of the System Configuration Utility could cause this. Array accelerator board configured for a different array controller board. Configuration signature on array accelerator board does not match the one stored on the array controller board. Controller communication failure occurred. EISA nonvolatile RAM does not contain a configuration for this controller. Controller firmware is below the latest recommended version. Recommended Action Not an error or data loss condition. No action required. Replace the array accelerator board. Run the System Configuration Utility. If 75% of batteries present are fully charged, array accelerator is fully operational. If less than 75% of batteries are fully charged, allow 36 hours to recharge them. Allow enough time for batteries to recharge (36 hours). If batteries have not recharged after 36 hours, replace the array accelerator board. Operate system without array accelerator board until Expand operation completes. Attach array accelerator board to array controller. Run the latest version of System Configuration Utility to configure the controller and nonvolatile RAM. To recognize the array accelerator board, run the Array Configuration Utility. ADU was unable to successfully issue commands to the controller in this slot. Run the System Configuration Utility to configure the nonvolatile RAM. Run Options ROMPaq to upgrade the controller to the latest firmware revision. continued