Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 161

messages. Run the System Configuration Utility, parity error was detected while

Page 161 highlights

3-64 Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide Table 3-16 ADU Diagnostic Messages continued Message Description WARNING: Storage enclosure on SCSI bus X indicated it is operating in single ended mode. One or more single-ended mode SCSI drives are installed in an external storage unit that operates in low voltage differential (LVD) mode. SOLUTION: This usually occurs when a single ended drive type is inserted into an enclosure with other drive types; and that makes the entire enclosure operate in single ended mode. To maximize performance replace the single ended drive with a type that matches the other drives. Write memory error Data could not be written to cache memory. This typically means that parity error was detected while writing data to cache. This could be caused by incomplete connection between cache and controller. This is not a data loss circumstance. Wrong Accelerator This could mean that either the board was replaced in the wrong slot or placed in a system that was previously configured with another board type. Included with this message is a message indicating (1) the type of adapter sensed by ADU and (2) the type of adapter last configured in EISA nonvolatile RAM. Recommended Action The array will continue to operate, but installing all low voltage differential (LVD) drives will maximize performance. With power to system turned off, verify that the cache board is fully connected to controller. Check the diagnosis screen for other error messages. Run the System Configuration Utility to update the system configuration.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231

3-64
Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide
Table 3-16
ADU Diagnostic Messages
continued
Message
Description
Recommended Action
WARNING:
Storage
enclosure on
SCSI bus X
indicated it is
operating in
single ended
mode.
SOLUTION: This
usually occurs
when a single
ended drive type
is inserted into
an enclosure
with other drive
types; and that
makes the entire
enclosure
operate in single
ended mode. To
maximize
performance
replace the
single ended
drive with a type
that matches the
other drives.
One or more single-ended mode
SCSI drives are installed in an
external storage unit that operates in
low voltage differential (LVD) mode.
The array will continue to operate, but installing
all low voltage differential (LVD) drives will
maximize performance.
Write memory
error
Data could not be written to cache
memory. This typically means that
parity error was detected while
writing data to cache. This could be
caused by incomplete connection
between cache and controller. This is
not a data loss circumstance.
With power to system turned off, verify that the
cache board is fully connected to controller.
Wrong
Accelerator
This could mean that either the board
was replaced in the wrong slot or
placed in a system that was
previously configured with another
board type. Included with this
message is a message indicating (1)
the type of adapter sensed by ADU
and (2) the type of adapter last
configured in EISA nonvolatile RAM.
Check the diagnosis screen for other error
messages. Run the System Configuration Utility
to update the system configuration.