System Unit, Table 5-1, System Unit Specifications - btu
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 202 highlights
5-2 Compaq ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maintenance and Service Guide System Unit Table 5-1 System Unit Specifications Dimensions Height Width Depth Weight (no drives and two power supplies) Temperature range Operating Shipping Relative humidity (noncondensing) Operating Nonoperating Maximum wet bulb temperature Input requirements (per power supply) Rated input voltage Rated input frequency Rated input current Input power Input power (BTU/hr) Power supply output power (per power supply) Rated steady-state power Maximum peak power 70.8 cm (27.88 inches) 48.6 cm (19.12 inches) 68.3 cm (26.88 inches) 54.0 kg (119 pounds) 10° to 35°C (50° to 95°F) -30° to 60°C (-22° to 122°F) 20% to 80% 5% to 90% 38.7°C (101.7°F) High Range 200 to 240 V 50 to 60 Hz 6 A 1700 W @ 220 V 5802 Btu/hr High Range 1150 W 1180 W Low Range 100 to 120 V 50 to 60 Hz 8 A 780 W @ 110 V 2662 Btu/hr Low Range 500 W 549 W