Compaq ProLiant 8000 ProLiant 8000 Intel Pentium III Xeon 700MHz Servers Maint - Page 124
Run Array Diagnostic Utility if, Run the Compaq Array
View all Compaq ProLiant 8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 124 highlights
Diagnostics and Troubleshooting 3-27 Table 3-2 POST Error Messages continued Error Code Audible Beeps 1785-Slot X Drive None Array not Configured (followed by one of the following): (1) Run Compaq Array Configuration Utility (2) No drives detected (3) Drive positions appear to have changed - Run Drive Array Advanced Diagnostics if previous positions are unknown. Then turn system power OFF and move drives to their original positions. (4) Configuration information indicates drive positions beyond the capability of this controller. This may be due to drive movement from a controller that supports more drives than the current controller. (5) Configuration information indicates drives were configured on a controller with a newer firmware version. (RESUME = F1 KEY) Probable Source of Problem Drive array configuration not detected. Recommended Action (1) Run the Compaq Array Configuration Utility. (2) Turn off system and check SCSI cable connections to make sure drives are attached properly. (3) Run Array Diagnostic Utility if previous positions are unknown. Then turn system power off and move drives to their original positions. (4) To avoid data loss, turn system power off and reattach drives to the original controller. (5) To avoid data loss, reattach drives to the original controller or upgrade the controller firmware to the version on the original controller using Option ROMPaq. Press F1 to resume. continued